SW1-8&7

BIAS-D RS-485/422 receiver line bias is disabled

BIAS-E RS-485/422 receiver line bias is enabled

The line bias is used to maintain the proper idle-state voltage to the idle condition (when no driver is enabled on the bus). These bias resistors are pull-up resistors on the data B line and pull-down resistors (to ground) on data A line. In 4-wire configuration, the bias resistors are placed on the receiver lines. [BIAS-D] disables the internal BIAS resistors on receiver lines.

[BIAS-E] setting enables internal bias resistors. The bias configuration can support up to 30 receiver nodes with no terminators. If the bias configuration is not proper for your physical topology, set to [BIAS-D] and use external bias design according to your application.

-26-

Page 26
Image 26
KTI Networks KSC-240 manual SW1-8&7