-43-
5 Factory Default Configuration
The following table lists the factory default settings for configuration
DIP SW:
SW Name Default Setting
SW1-2&1 4W 4-wire (RS-485/422 driver receiver separated)
SW1-3 T-D (Off) Disable RS-485/422 receiver terminator
SW1-4 TXC (Off) RS-485/422 driver enable control by RTS or ADC
SW1-5 RTS-D(Off) Disable RTS control for RS-485/422 driver
SW1-6 RXC (Off) RS-485/422 receiver enable control by RTS or ADC
SW1-8&7 BIAS-D (Off) Disable RS-485/422 line bias
SW2-1 SDE (On) Enable ADC control for RS-485/422 driver
SW2-2 Off Disable ADC Timing for RS-232 baud 1200
SW2-3 Off Disable ADC Timing for RS-232 baud 2400
SW2-4 Off Disable ADC Timing for RS-232 baud 4800
SW2-5 9600 (On) Select ADC Ti ming for RS-232 baud 9600
SW2-6 Off Disable ADC Timing for RS-232 baud 19200
SW2-7 Off Disable ADC Timing for RS-232 baud 38400
SW2-8 Off Disable ADC Timing for RS-232 baud 115200