7
0.090> 2.3
roaring, flickering flame
ideal operating range
0.050> 1.4
0.035> | 0.95 |
|
| weak, sooty flame |
| |
0.020> | 0.5 |
|
|
|
|
|
____________________________________________________ | ||||||
| 1 | 2 | 3 | 4 | 5 | 6 |
|
| Position of the carburetor knob |
|
draft in mm water gauge draft in inches water gauge
SECTION 5
Servicing
ANNUALLY:
*Remove catalyst and fire ring and inspect and clean out burn pot of any
*Check flue and clean out soot
*Lightly brush off catalyst and inspect for deterioration– replace if necessary.
*Check all gaskets: rope seal around door, window seal (check for loose glass– no need to remove), access panel gaskets.
*Check oil tank for damage or leaks and clean or replace main tank filter. *Check all lines and connections for leaks or deterioration.
*A draft reading should be taken for low– and
QUARTERLY:
*Turn stove off and allow to cool.
*Remove catalyst and clean out any carbon deposits from burner bottom and oil inlet inside burner (may need to clean deposits more frequently if using #2 fuel).