99637591_A_EN.qxp 19/07/2005 12:57 Page 16
4 / SPECIAL MESSAGES, DIFFICULTIES
You have doubts about whether your hob is working correctly. This does not necessarily mean that there is a breakdown. Nevertheless, check the following points.
PROBLEM | POSSIBLE CAUSES | WHAT SHOULD YOU DO? |
|
|
|
When you switch the unit on, the
When you switch elements on, only one element works.
The fans keep running for a few minutes after the unit has been switched off,
The top of the unit is always lukewarm (even when elements are not switched on).
Your hob makes faint clicking noise when in operation.
The unit doesn't work at all.
After turning an element ON and having utensil placed on the coil, there is no heat and the digital indicator continues flashing..
Utensil makes noise during cooking.
The hob gives off a smell when first used for cooking.
Your unit may be connected incorrectly,or there is an internal problem.
There is an internal problem with the unit.
The electronics are cooling down
The electronic components are under power and they create heat.
This noise occurs when the power is being shared between two induction coils.
There may be a power supply or internal problem.
The utensil you are trying to use is not compatible with induction cooking or its diameter is under 10 cm. (4”).
Your utensil creates noise from vibrations caused by induced current .
A new unit
Have the connection checked first. If the connection is OK, contact your service agent.
Contact your service agent.
This is a normal occurrence.
This is a normal occurrence.
This is a normal occurrence.
Check your beakers (fuses) and/or connection cable.
If OK, contact your service agent.
Use another utensil suitable for induction cooking.
Under high power this phenomenon is normal with some types of pots and pans. There is no danger for the hob.
Use each heating element for an hour with a pan filled with water.
Servicing of an induction unit is to be done by an authorized
service agent. Contact your dealer for service location closest to
your residence. Never try servicing the unit yourself.
If any crack on the vitroceramic glass can be noticed, or the glass
is broken DO NOT USE THE UNIT. Disconnect the electrical
supply to the unit by tripping the breaker off (if the unit is hard- wired to the supply) or just unplug the unit (if there is a plug on the supply cable).
16