Kuppersbusch USA GMS 6540.0 E-UL, GMS 9551.0 E-UL Conversions, Replacing The Injectors

Models: GMS 9551.0 E-UL GMS 6540.0 E-UL

1 16
Download 16 pages 34.37 Kb
Page 12
Image 12
CONVERSIONS

CONVERSIONS

11) REPLACING THE INJECTORS

The burners can be adapted to different types of gas by mounting injectors suited to the type of gas in question. To do this, first remove the burner tops using a wrench “B”. Now unscrew injector “A” (see fig. 10) and fit a injector corresponding to the utilized type of gas in its place.

It is advisable to strongly tighten the injector in place.

After the injectors have been replaced, the burners must be regulated as explained in

paragraphs 10. The technician must reset any sealsontheregulatingorpre-regulatingdevices. Theenvelopewiththeinjectorsandthelabelscan be included in the kit, or at disposal to the authorizedcustomerServiceCentre.

For the sake of convenience, the nominal rate table also lists the heat inputs of the burners, the diameter of the injectors and the working pressures of the various types of gas.

BURNERARRANGEMENTONTHEHOTPLATE

1

2

3

4

5

TABLE

 

 

 

 

 

 

BURNERS

 

NORMAL

INJECTOR

NOMINALHEAT

GAS

PRESSURE

DIAMETER

INPUT(Btu/h)

DESCRIPTION

incheswater

 

 

 

1/100 mm

Min.

Max.

 

column

ULTRARAPID

PROPANE HD - 5

11

94

4400

11000

NATURALGAS

7

176

4400

11000

 

RAPID

PROPANE HD - 5

11

91

2500

10000

NATURALGAS

7

155

2500

10000

 

SEMIRAPID

PROPANE HD - 5

11

70

1500

6100

NATURALGAS

7

120

1500

6100

 

SEMIRAPID

PROPANE HD - 5

11

70

1500

6100

NATURALGAS

7

120

1500

6100

 

AUXILIARY

PROPANE HD - 5

11

53

1200

3550

NATURALGAS

7

90

1200

3550

 

 

 

 

 

 

 

FIG. 10

12

Page 12
Image 12
Kuppersbusch USA GMS 6540.0 E-UL, GMS 9551.0 E-UL Conversions, Replacing The Injectors, Burnerarrangementonthehotplate