5.Accessories supplied

1120/150 mm reduction

2wall support for tubecover

2wall plugs (Ø9x40)

2long bolts (Ø9x40)

6wall plugs (Ø5x40)

6long bolts (Ø5x40)

2active carbon filters (optional)

6.Installation

On installing the kitchen hood make sure thet Safety Instructions set out on page 14 are complied with.

To obtain optimum performance, the external duct must not to be more than FOUR METERS LONG, have no more than two 90° angles and its diameter must be at least Ø120.

6.1 Installing: Trenti / Nubero / Ventoline

fig.5

1.Mount the 150/120 reduction whenever the air discharge tube is Ø125 (fig.7);

2.Trace and drill the points for fitting the wall plugs (H Ø9x40) and (L Ø5x30) onto the wall at the desired height by leaning the hood on the wall, then tighten the long bolts (H);

3.Hang the kitchen hood, hooking its support

onto the long bolts (H) as in fig.5b and then tighten the long bolts (L);

4.Trace and drill the location of the lower support

(G)of the tubecover, fit the wall plugs (M) and fix it by using the bolts (M), then hook the fixed chimney to its support (G) as in fig.5c;

5.Mount the mobile chimney and lift it up to the desired height and mark its shape on the wall;

6.Remove the fixed and mobile chimneys;

7.Centre the upper support (G) around the shape marked, trace and drill the fixing points for fitting wall plugs (M), then fix the support

(G) by using bolts (M);

8.Attach the inner tube, possibly flexible, with a clamp (not supplied) to the motor’s air outlet or to the 150/120 reduction as the case may be (fig.7);

9.Once the inner tube is fitted, fit the fixed and mobile chimney around the extractor fan outlet and hook them onto respective supports;

10.Connect the scavenging pipe to the outdoor duct and fix it with a pipe tightening clamp.

6.2Installing: Laro

fig.6

1.Mount the 150/120 reduction whenever the air discharge tube is Ø125 (fig.7);

2.Trace and drill the points for fitting the wall plugs (H Ø9x40) and (L Ø5x30) onto the wall at the desired height by leaning the hood on the wall, then tighten the long bolts (H);

3.Hang the kitchen hood, hooking holes (I) onto the long bolts (H) as in fig.6b and then tighten the long bolts (L);

4.Trace and drill the location of the lower support

(G) of the tubecover, fit the wall plugs (M) and fix it by using the bolts (M), then hook the fixed chimney to its support (G) as in fig.6c;

5.Mount the mobile chimney and lift it up to the desired height and mark its shape on the wall;