802 141 Installation and service instructions
03/00
ARMATUREN
ROBINETTERIE
RUBINETTERIA
GRIFERIA
FAUCETS
Concealed pressure balanced bath and shower mixer | KWC MARLINO |
4 port with diverter | + | 4 port without diverter | / | 3 port |
| Inlet: |
|
|
| cold |
|
|
Inlet: | water |
| with integrated |
hot |
|
| twin ell not required |
water |
|
| |
Rough in: |
| Rough in: | Rough in: |
K.37.P4.01.931.23 |
| K.37.P4.02.931.23 | K.37.P4.03.931.23 |
Trim set:
KWC MARLINO K.20.P4.00
Trim set:
KWC MARLINO K.21.P4.00
Trim set:
KWC MARLINO K.21.P4.00
This product is precision engineered to provide superior
!performance provided it is installed and operated in accordance with these recommendations. In order to fully enjoy the comfort, safety and reliability of your
pressure balancing valve, be certain to familiarize yourself with these instructions.
Failure to follow these instructions may cause damage or improper operation and nullify the warranty!
Maintenance:
A)To clean your faucets and accessories simply wipe them with a
wet, soapy cloth, immediately rinse off with cold watre and wipe dry with
a soft, damp cloth or towel.
B)Most bathroom and kitchen cleaners contain aggressive (acidic / corrosive) chemicals or abrasives which will harm the finish and cause operational problems.
C)Use of these products voids the manufacturer's warranty.
Operation:
A counterclockwise rotation opens the valve beginning with cold water. Preventing accidental scalding.
An adjustable hot limit stop reduces risk of exposure to extremely hot water.
Clockwise rotation of the handle closes the valve.
The valve's comfort zone ensures a safe, |
|
|
|
|
|
|
|
reliable and precise adjustment of mixed |
|
| fort | z |
|
|
|
|
| m |
|
|
| ||
water temperature in the range from |
| o |
| o |
|
| |
105˚F | C |
|
| n | 95˚F | ||
95° F (35°C) to 105°F (40°C). |
|
|
| e | |||
40˚C |
|
|
|
|
| 35˚C | |
The featherlight touch of the handle |
|
| KWC |
|
|
|
|
provides simple and easy control for |
|
|
|
|
|
|
|
the young or elderly.
E | Operating data |
|
|
|
|
|
| |
Ideal operating | pressure | : | 3 bar (45 PSI) |
|
| |||
|
|
|
| |||||
|
| Max. operating | pressure | : | 5 bar (70 PSI) |
|
| |
|
| Equal pressures cold/warm recommended |
|
| ||||
|
| Ideal water temperature | : 65 °C (149°F) |
|
| |||
|
| Max. hot water temperature | : | 90 °C (194°F) |
|
| ||
|
|
|
|
|
|
|
|
|
|
| Attention: |
|
|
|
|
|
|
| ! | Before installation flush pipes thoroughly! |
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Schweiz, Suisse: |
| USA: |
|
|
|
| |
| KWC AG |
| KWC FAUCETS INC. | |||||
| Hauptstrasse |
| 1770 Corporate Drive # 580 | |||||
|
| Norcross, GA 30093 | ||||||
| Tel. : 062 768 67 77 |
| Phone: 678 334 2121 | |||||
| Fax : 062 768 61 62 |
| Fax: | 678 334 2128 |
|
|
|