KWC 802 141 warranty Installation Back-to-back

Models: 802 141

1 4
Download 4 pages 27.24 Kb
Page 3
Image 3

Installation Back-to-back

¡

¿

3

(if applicable)

 

 

 

 

 

 

 

 

 

¬

 

 

 

 

 

￿

 

 

stop ring (3)

stop ring (3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screw (1)

 

 

 

shut-off valves

 

 

 

valve steam

stop post

 

 

 

 

 

driver (2)

 

(downward)

¿

 

 

 

 

 

 

 

cartridge stem

stop ring

 

 

 

 

 

 

 

 

 

close

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

(4)

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

(6)

 

 

stop post

 

 

 

 

 

 

(5)

 

 

(downward)

 

 

 

 

 

 

 

 

 

 

 

 

Close shut-off valves:

 

 

 

 

- Put the O-ring on the valve cover. Make sure the surface of the valve

-

Once shower enclosure is completed, remove the finished wall template.

 

 

cover, on which the O-ring will sit, and the O-ring are both clean.

¡

-

If the valve body is equipped with service stop valves close the hot and

￿

-

Position the valve cover with stop post facing

down. Seat the cover to the

 

cold water supplies. Otherwise, shut the supply at the nearest source.

 

body. Do not pinch the O-ring. The assembly should fit together with a

 

 

 

 

 

 

minimum

of pressing force.

 

 

Remove valve stem driver and stop ring:

- Tighten up the cover screws diagonally, first lightly and then more

-

Remove the screw (1) to remove the plastic valve stem driver (2).

 

firmly.

 

 

 

¬

-

Remove stop ring (3) note position.

 

 

 

 

 

 

 

 

 

 

Fix stop ring on closed position:

 

 

Turn cartridge for back-to-back installation:

-

Close the

valve by turning the

cartridge stem

clockwise.

-

Remove the four cover screws (4) and the valve cover (5) with O-ring (6).

 

- Position the stop ring on the stem as shown in figure 4.

 

- Pull the cartridge out. Do not damage the O-ring seals.

 

- Install plastic stem driver (2) with screw (1).

 

 

-

Rotate the cartridge 180°

turning

it upside down. Place it into the valve

 

 

¡

 

 

 

 

 

body. Note position of hot ("H") and cold ("C") markings on the cartridge:

 

 

 

 

 

 

 

"H" hot will now be on the right and "C" cold on the left. Two alignment pins

 

 

 

 

 

 

 

located on the rear of the cartridge must sit in the locating holes within the

 

 

 

 

 

 

 

valve body. Cartridge is correctly

engaged when pushing the cartridge, it

 

 

 

 

 

 

 

will not rotate.

 

 

 

 

 

 

 

 

Installation of the trim set and setting the hot limit stop

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

(7)¿

Do not overtighten !

 

 

A)

 

B)

 

 

 

 

 

close

hot limit ring (10)

 

 

 

 

 

 

 

 

 

 

 

 

valve stem

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

driver (2)

 

 

 

 

 

 

 

 

 

(1)

(7)

rotating of the stem

 

 

 

 

 

(9) to the desired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max. temperature

 

 

¿

!

 

 

 

¡

 

max. hot temperatur

(9)

stop post

 

 

 

(8)

 

 

 

Torx 20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation of the escutcheon (8):

 

Setting hot limit stop:

 

 

 

 

 

 

 

 

 

 

 

 

 

Install escutcheon screws (7) into valve cover posts.

 

A) Rotate escutcheon driver stem (9) counterclockwise until a desired and safe

 

Slide the escutcheon (8) over the screw heads and rotate escutcheon

 

 

hot water temperature is reached (recommened maximum is 110°F / 43°C)

 

counterclockwise.

 

 

 

 

B) Place the hot limit ring (10) over the splines on the stem (9) with the hot limit

 

Tighten the screws (7) so the escutcheon is firmly pressed against the wall and

 

 

ring resting against the stop post on the escutcheon.

 

does not rotate. Do not overtighten!

 

 

Closing the valve while rotating the stem (9) clockwise until it stops,

 

 

 

 

 

 

¬Install the handle.

 

 

Page 3
Image 3
KWC 802 141 warranty Installation Back-to-back, Installation of the trim set and setting the hot limit stop