KD 200-60 P Series

Electrical SPECIFICATIONS

Standard Test Conditions (STC)

STC = 1000 W/M2 irradiance, 25oC module temperature, AM 1.5 spectrum*

KD240GX-LPB KD245GX-LPB

Pmp

240

245

W

Vmp

29.8

29.8

V

Imp

8.06

8.23

A

Voc

36.9

36.9

V

Isc

8.59

8.91

A

Ptolerance

+5/-3

+5/-3

%

Nominal Operating Cell Temperature Conditions (NOCT)

NOCT = 800 W/M2 irradiance, 20oC ambient temperature, AM 1.5 spectrum*

T

45

45

oC

NOCT

 

 

 

Pmax

172

176

W

Vmp

26.7

26.8

V

Imp

6.45

6.58

A

Voc

33.7

33.7

V

Isc

6.95

7.21

A

PTC

217.3

219.1

W

Temperature Coefficients

P

-0.46

-0.46

%/oC

max

 

 

 

V

-0.52

-0.52

%/oC

mp

 

 

 

I

0.0064

0.0065

%/oC

mp

 

 

 

V

-0.36

-0.36

%/oC

oc

 

 

 

I

0.060

0.060

%/oC

sc

 

 

 

Module Characteristics

Dimensions:65.43in/38.98in/1.8in

length/width/height(1662mm/990mm/46mm)

Weight:

46.3lbs (21.0kg)

 

 

PACKAGING SPECIFICATIONS

Modules per pallet:

 

20

Pallets per 53’ container:

 

36

Pallet box dimensions:

 

66.54in/39.76in/47.24in

length/width/height

 

 

(1690mm/1010mm/1200mm)

Pallet box weight:

 

 

1050 lbs (480kg)

 

 

4.84in

1.8in

 

 

123mm

46mm

11.06in 281mm

 

3.61in 91.6mm

 

(IP65)

 

 

 

 

 

 

37.8in 960mm

 

46.9in 1190mm

21.65in 550mm

 

 

 

STABILIZER BAR

 

 

 

 

 

 

 

 

1.54in

 

 

 

 

39mm

65.43in 1662mm

 

1.47in 37.3mm

0.06in 1.6mm

 

21.65in 550mm

Stabilizer Cross Section Diagram

 

 

 

 

STABILIZER BAR

11.06in 281mm

 

38.98in

.49in

990mm

12.5mm

 

.47in

 

12mm

Operating

-40 to +90

-40 to +90

oC

Temp

 

 

 

System Design

 

 

 

Series Fuse Rating

 

 

15 A

Maximum DC System Voltage (UL)

 

600 V

11.06in 281mm

1.30in

33mm

1.8in 46mm

Short Side

.41in

10.3mm

1.8in 46mm

Hailstone Impact

1in (25mm) @ 51mph (23m/s)

*Subject to simulator measurement uncertainty of +/- 3%.

KYOCERA reserves the right to modify these specifications without notice.

NEC 2008 Compliant

 

 

 

WARNING: Read the instruction

 

 

 

manual in its entirety prior to

UL 1703 Listed

 

 

 

handling, installing & operat-

Certified IEC61215 Ed2 IEC61730 by JET

ing Kyocera Solar modules.

 

021313

 

 

 

 

 

 

 

 

Long Side

 

.79in

 

 

 

 

 

 

20mm

 

 

Expanded View of Grounding Holes

Frame Cross Section Diagrams

MOUNTING HOLES DRAINAGE HOLES

 

GROUND SYMBOL

 

.35in (9mm)

 

.35in (9mm)

 

 

 

Our Valued Partner

KYOCERA Solar, Inc. 800-223-9580 800-523-2329 fax www.kyocerasolar.com

Page 2
Image 2
Kyocera KD245GX-LPB KD 200-60 P Series, Standard Test Conditions STC, Nominal Operating Cell Temperature Conditions Noct