LaCie 12big rack serial I/O Module
Quick Install Guide page 9
ops Panel LEDs
other
associated LEDs or alarms State Description
Power on
(green)
System Fault
(amber)
Logical Fault
(amber)3
Box identify
(Blue)
On On On On 12big rack serial Module activity LEDs flash Ops Panel power on test state.
On Off any any Power On. All functions good.
On On any any Dual Fan Cooling Module Fault LED on.
Continuous beep.
Dual Fan failure.
On Flash any any Dual Fan Cooling Module Fault LED on.
Intermittent beep.
Single Fan failure.
On Flash any any PSU Module Fault LED on.
Intermittent beep.
Single PSU failure.
On Flash any any Intermittent beep. PSU removed.
On Flash any any Intermittent beep. Over or under temperature warning.
On On any any Continuous beep. Over or under temperature critical.
On On any any Continuous beep. Voltage critical.
On Off As per Drive fault
LED
any None Drive critical.
On Off As per Drive fault
LED
any None Drive non-critical.
On On any any 12big rack serial Fault & ID LEDs on.
Continuous beep.
12big rack serial Module watchdog failure.
On Flash any any212big rack serial Fault & ID LEDs on.
Internittent beep.
12big rack serial Module soft (or POST)
failure.
On Flash any any212big rack serial Fault & ID LEDs on.
Intermittent beep.
Other 12big rack serial Module fault.
LED operation set via SES Control page 0x02
On any Off any Power On. All functions good.
On any As per Drive fault
LED
any Drive Bay Fault LED ash. POST fault bit set for any Array Device
Element.
On any As per Drive fault
LED
any Drive Bay Fault LED ash. Other Array bits set for any Array Device
Element.
On On any any Continuous beep. UNRECOV bit set in Audible Alarm element.
On any any any Intermittent beep. INFO, NON-CRIT, CRIT bits set in Audible
Alarm element
On any any any Continuous beep. UNRECOV bit set in Audible Alarm element.
On Flash any any REQUEST WARNING bit set in Enclosure
element.
On On any any REQUEST FAILURE bit set in Enclosure
element.
On any any Flash RQST IDENT bit set in Enclosure element.

notes

The 12big rack serial alarm pattern is a 1 second on, 1 1.

second off sequence, applied to all 12 Activity LEDs.

If an 12big rack serial fault LED is fitted, this will be set for 2.

all the above conditions. In addition this LED will flash for

an 12big rack serial module soft failure.

The Logical Fault LED will take the state of the highest 3.

priority drive bay fault LED.