Pick up cool air at floor level and recirculate throughout room. Windows should be closed so that hot air will not enter home.

BY NIGHT

Use as Exhaust Fan

Pull cool outside night air through home and exhaust hot stale air through “exit” window. Create many air streams by opening windows and doors as shown. Fan should be positioned approximately 2 feet from window. DO NOT,

HOWEVER, OPERATE FAN WHILE UNATTENDED.

CARE AND CLEANING

This fan should be cleaned on an as needed basis to prevent restricted air flow of both grilles and motor. BEFORE CLEANING THE FAN UNPLUG THE POWER CORD. Remove front grille by removing screws. Wash grilles and blades with water and soft brush. Avoid harsh chemical cleaners. DO NOT IMMERSE THE MOTOR IN WATER.

Allow fan to dry completely before use.

Excess dust accumulated on the vent slots of the motor can be easily removed with a vacuum cleaner. Your fan motor is permanently lubricated and requires no additional oil.

FAILURE TO PROPERLY CLEAN AND MAINTAIN THE FAN WILL VOID THE MANUFACTURER'S WARRANTY.

LIMITED WARRANTY

(as defined by Magnuson-Moss Warranty - Federal Trade Commission Improvement Act)

This unit is guaranteed to the original retail purchaser against defects in quality or workmanship for a period of five years from the date of original purchase if purchased within the continental United States. If purchased outside the continental United States this product has a one year warranty.Ifthisunitfailsbecauseofamanufacturingdefect within30daysofpurchase,returntheunitwithyourreceipt, to the retailer. After 30 days, but within the warranty period, if the unit was purchased within the continental United States, return it, freight prepaid, to Lakewood Engineering

&Mfg. Co. for repair or replacement. If the unit was purchased outside the continental United States return the unit to the place of purchase. This warranty does not cover damage due to accidents, operation on other than 120 volts 60 hertz, A.C. current, or any other abuse.

All implied warranties, including the warranties of mer- chantability and of fitness of purpose, if applicable, are herebylimitedindurationtotheperiodoffiveyearsfromthe day of original retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

Incidentalorconsequentialdamagesarisingfromabreach of either express or implied warranties are hereby dis- claimed and excluded. Some states do not allow the exclusion of limitation of incidental or consequential dam- ages, so this limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

No informal dispute settlement mechanisms are available. This limited warranty is given in lieu of all other warranties.

Manufactured by:

LAKEWOOD ENGINEERING & MFG. CO., INC. 501 N. Sacramento Blvd., Chicago, IL 60612 U.S.A.

(Visit our website at www.lakewoodeng.com) Repair parts can be ordered from our website.

If you have problems, questions or comments about your new Lakewood Fan, contact our Customer Service Department at 1-888-858-3506, Monday through Friday - 8:00 a.m. - 5:00 p.m. C.S.T.

Page 3
Image 3
Lakewood Engineering HV-21, HV-18 manual Care and Cleaning, Limited Warranty, By Night, Use as Exhaust Fan

HV-18, HV-21 specifications

Lakewood Engineering has established itself as a prominent name in the world of innovative machinery, particularly with its HV-21 and HV-18 models. These machinery pieces have garnered attention for their impressive capabilities and cutting-edge technologies.

The HV-21 is engineered for heavy-duty performance, making it suitable for a variety of industrial applications. One of its hallmark features is its robust construction, allowing it to withstand rigorous operational demands. It is equipped with a high-capacity motor that delivers superior torque and power while maintaining energy efficiency. The advanced hydraulic system ensures precise control and smooth operation, making it an ideal choice for operations that require meticulous handling of materials.

On the other hand, the HV-18 model is designed for versatility and adaptability. It features a more compact design than the HV-21, making it easier to maneuver in tighter spaces. This model incorporates a user-friendly control panel that offers intuitive operation, allowing operators to quickly engage with the machine's functions without extensive training. The HV-18 also boasts an advanced safety mechanism, ensuring that operators are protected during operation.

Both models benefit from Lakewood Engineering’s commitment to advanced technology. They are integrated with state-of-the-art digital monitoring systems that provide real-time data on performance metrics. This technology allows for predictive maintenance, reducing downtime and enhancing productivity. Operators can adjust settings remotely, maximizing efficiency and reducing the need for on-site management.

Another noteworthy characteristic of the HV-21 and HV-18 is their emphasis on environmental sustainability. Both models are designed with energy-saving features, minimizing their carbon footprint while delivering optimal performance. This aligns with the growing trend towards eco-friendly machinery in the industrial sector.

In summary, Lakewood Engineering’s HV-21 and HV-18 models exemplify a blend of power, precision, and innovation. They cater to various industry demands, from heavy-duty applications to versatile operations, while incorporating advanced technologies and safety features. With a focus on sustainability, these machines position themselves as leading solutions in the modern engineering landscape, paving the way for future advancements in industrial machinery.