Lanier Worldwide, Inc.
2300 Parklake Drive, NE
Atlanta, GA USA
MATERIAL SAFETY DATA SHEET
Emergency Telephone: 800-526-4371
Section 1: Chemical Product and Company Information
Identity: | TDC10 Black Toner Cartridge | MSDS No. | CP- 282 |
Product ID: | Issued: | 06/15/2004 | |
Synonyms |
| Supersedes: | 05/08/1995 |
Date: | 06/15/2004 | ||
& Common | Black Toner for | Prepared by: | EH&S Department |
Names: | Lanier 6610 | Approved by: | Larry Choskey, Manager, CEH&S |
Uses: |
| European | Walter Fricke, Manager, Safety & |
Lanier 6610 Copier | Contact: | Environment, | |
Chemical |
|
| Lanier Worldwide, Inc. |
|
| Im Taubental | |
Formula: | Mixture |
| Germany |
Section 2: Composition / Information on Ingredients
Toner Component | Percent | CAS No. | Exposure Limits | Source |
Styrene acrylate copolymer | 92 | Not listed | n/a | |
Carbon black | 4 | 3.5mg/m3 | OSHA PEL | |
|
|
| 3.5mg/m3 | ACGIH TWA |
Organic pigment | 4 | Not listed | N/a | |
Developer Component | 93.5 | Not listed | N/a | |
Iron powder | ||||
Carbon black | 0.3 | 3.5mg/m3 | OSHA PEL | |
Difluorethylene polymer | 0.5 | 3.5mg/m3 | ACGIH TWA | |
Not listed | N/a | |||
Styrene acrylate copolymer | 5.5 | Not listed | n/a | |
Organic pigment | 0.2 | Not listed | N/a |
*PEL as the product: 15mg/m3 (total dust), 5mg/m3 (respirable dust)
*TLV as the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust)
| Section 3: Hazards Identification |
|
HMIS Rating: | HEALTH = 1 |
|
FLAMMABILITY = 1 |
| |
REACTIVITY = 0 | SPECIAL = none |
|
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any
Health Hazards of Long Term exposure (Chronic): Prolonged inhalation of excessive dust may cause lung damage. It is attributed to “lung overloading”, a generic response to excessive amounts of any dust retained in the lungs for a prolonged interval. Use of this product, as intended, does not result in inhalation of excessive dust.
Carcinogenicity: Carbon Black was reclassified as a Group 2B by the IARC in 1996 based upon the result of only the inhalation study in rats. However, there was not observed the incidence of tumors on the test results on dermal or oral studies. Also,
Section 4: First Aid Measures
Inhalation: | Gargle with water. Remove to fresh air if effects | Eye Contact: | In case of contact, immediately flush eyes |
occur. Get medical attention if needed. | with water for 15 minutes. Get medical | ||
Skin Contact: | Wash with soap and water. | Ingestion: | attention if needed. |
Dilute stomach contents with several | |||
|
|
| glasses of water. Get medical attention. |
| Section 5: Fire Fighting Measures |
| |
Suitable extinguishing media: CO2, dry chemical, foam or water. | Extinguishing media which may not be used for safety | ||
|
| reasons: none | |
Special protective equipment for fire fighters: none |
|
| |
UEL: n/a | LEL: n/a |
|
|
y o u r d o c u m e n t m a n a g e m e n t p a r t n e r