CLEARANCES TO COMBUSTIBLE MATERIALS / FLOOR PROTECTION

¥The location should also be free of electrical, plumbing or other heating/air conditioning ducting.

¥Due to high temperatures, this appliance should be located out of trafÞc and away from furniture, draperies and not in windy or drafty areas.

¥This appliance can be installed in most residential room conÞgurations, parallel to a rear or adjacent wall, or in an alcove that allows for the minimum clearances to combustible surfaces. Your local building inspector should review your plans prior to installation.

¥When installing this appliance, provide adequate clearances for the purposes of servicing and proper operation.

¥As determined through the safety certiÞcation of this unit, a minimum clearance to combustible materials must be maintained around speciÞc areas of the gas appliance. (See Table 5 & Figure 2)

CLEARANCES

 

 

CI1500DVF

CI2500DVF

 

A (minimum)

*10” (254 mm)

*10” (254 mm)

 

B (minimum)

*14-1/4” (362 mm)

*17-1/4” (438 mm)

 

 

 

 

 

 

 

C (minimum)

*15-7/8” (403 mm)

*19” (483 mm)

 

D (minimum)

4” (102 mm)

 

 

4” (102 mm)

 

E (minimum)

2” (51 mm)

2” (51 mm)

 

F (minimum)

4” (102 mm)

4” (102 mm)

 

G (minimum)

0” (0 mm)

 

 

0” (0 mm)

 

H (minimum)

***62” (1575 mm)

***62” (1575 mm)

 

I (minimum)

**28 1/2” (724 mm)

**34 1/2” (876 mm)

 

J (MAXIMUM)

48” (1219 mm)

48” (1219 mm)

 

 

 

 

 

 

Table 5

*Dimensions with a single asterix are reference dimensions only.

**If the optional warming shelves are installed, a greater alcove width is required as follows:

CI1500DVF - 44" (1118 mm) min.

CI2500DVF - 52 1/2" (1334 mm) min.

***This includes any projections such as shelves, windowsills, mantels, etc. above the appliance.

Note: Recommended clearance zone from the front of the appliance to combustibles is 36 inches (914 mm) minimum.

Floor Protection

When installed directly on carpeting, tile (see Note below) or other combustible material other than wood ßooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the stove body.

Note: Ceramic tile is non-combustible and does not require a wood or metal panel under the appliance.

Clearance To Combustibles

& Alcove Dimensions

Side View / Rear Wall or Alcove Clearances

*A

H

D

L E N N O X

G J

Top View / Rear Wall or Alcove Clearances

D

*B

EE

I

Top View / Corner Clearances

F

*C

F

Vent Clearances - All Models

For Horizontal Sections: Top - 3" (76.2 mm) min. Sides - 1" (25.4 mm) min. Bottom - 1" (25.4 mm) min.

For Vertical Sections:

Sides - 1" (25.4 mm) min.

At Wall Firestops:

Top - 3" (76.2 mm) min. Sides - 1" (25.4 mm) min. Bottom - 1/2" (12.7 mm) min.

Figure 2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

5