MANUFACTURED (MOBILE) HOME REQUIREMENTS

These models may be installed in an after- market permanently located, manufactured home, where not prohibited by local codes. When installed in Manufactured Housing the following supplemental requirements must be met:

¥

The appliance must be secured to the ßoor

 

(i.e. use (4) ¼Ó x 2 ¾Ó bolts and nuts or

 

equivalent. Note: Not included) for securing

 

appliance to the manufactured home ßoor.

¥

The appliance must be grounded to the

 

chassis of the manufactured home. Use a

 

No. 8 or heavier copper wire at least 18Ó in

 

length.

¥

The structural integrity of the manufactured

 

home ßoor, walls, ceiling and roof must be

 

maintained.

¥

A manufactured (mobile) home installation

 

must conform with the Manufactured Home

 

Construction and Safety Standard, Title 24

 

CFR, Part 3280, or, when such a stan-dard

 

is not applicable, the Standard for Manufac-

 

tured Home Installations, ANSI / NCSBCS

7.Are below grade penetrations of the gas line allowed?

8.Is concealed gas piping allowed?

9.SpeciÞ c requirements of concealed Þ t- tings?

10.Is rigid pipe to appliance required?

11.Allowed piping materials?

12.Shut-off valve required within 4 feet of the Þrebox?

13.May the shut-off valve be concealed?

14.Rooms where the installation is not allowed?

In the absence of local codes, installation should conform to National Fuel Gas Code, ANSI Z223.1 / NFPA 54-Latest Edition in the USA or National Fuel Gas Code, CAN/CGA- B149-Latest Edition in Canada.

VENT TERMINATION CLEARANCES

Vertical Vent Termination Clearances

TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS

Horizontal Overhang

These instructions should be used as a guideline and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 and -B149.2 in Canada.

Horizontal Vent Termination Clearances

The horizontal vent termination must have a minimum of 3" (76 mm) clearance to any overhead combustible projection of 2 1/2" (64

mm)or less. See Figure 4. For projections exceeding 2 1/2" (64 mm), For additional vent location restrictions refer to Figure 5.

Horizontal Vent Termination Clearances

Combustible Projection 2 1/2 inches or less in length

Combustible Projection greater than 2 1/2 inches in length

Ventilated

Soffit Unventilated

Soffit

A225.1, or standard for Gas equipped

Recreational Vehicles and Mobile Housing,

CSA Z240.4.

QUESTIONS TO ASK LOCAL BUILDING OFFICIAL

This appliance must be installed per manu- facturersÕ instructions.

Installations must conform to appropriate

2 FT MIN.

Vent Termination

Storm Collar

Flashing

Concentric

Vent Pipe

2 FT

Vertical

MIN.

Wall

 

Lowest

 

Discharge

 

Opening

 

H*

X

 

 

12

Roof Pitch is X/12

1 inch (25.4 mm) Minimum Clearance to Combustibles

*H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT

 

 

 

 

 

 

 

3"

3"

18"

12"

 

 

(76 mm)

 

 

(76 m

(457 mm)

(305 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Termination Kit

1"

(25 m

Note - See vent manufacturer's instructions for recess allowances, into exterior walls for the horizontal termi-

local codes and applicable state and federal requirements. Familiarity with these requirements before installation is essential. Some important considerations to discuss with local building ofÞcials include:

1.Applicable codes (i.e. Uniform Mechanical Code, State or Regional Gas Codes, National Fuel Gas Code)

2.Local amendments

3.Recognized testing lab: OMNI-Test Labora- tories Inc.; Beaverton, Oregon

4.Is a permit required - cost?

5.In some states or municipalities, a licensed gas Þtter or plumber may be required to install this appliance. Check with your local building ofÞcial for requirements in your area (i.e. Is a license required for installation of gas supply line)?

6.Maximum amount of gas pipe without a pressure test - type of test required?

6

The vent/air intake termination clearances above the high side of an angled roof is as

follows:

 

 

Roof Pitch .................

Feet

Meters

Flat to 6/12 ................

1.0

0.3

6/12 to 7/12...............

1.25

0.38

7/12 to 8/12...............

1.5

0.46

8/12 to 9/12...............

2.0

0.61

9/12 to 10/12.............

2.5

0.76

10/12 to 11/12...........

3.25

0.99

11/12 to 12/12...........

4.0

1.22

12/12 to 14/12...........

5.0

1.52

14/12 to 16/12...........

6.0

1.83

16/12 to 18/12...........

7.0

2.13

18/12 to 20/12...........

7.5

2.29

21/12 to 21/12...........

8.0

2.44

Figure 3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

nation caps.

Figure 4

Side Elevation View