MANUFACTURED (MOBILE) HOME REQUIREMENTS
These models may be installed in an after- market permanently located, manufactured home, where not prohibited by local codes. When installed in Manufactured Housing the following supplemental requirements must be met:
¥ | The appliance must be secured to the ßoor |
| (i.e. use (4) ¼Ó x 2 ¾Ó bolts and nuts or |
| equivalent. Note: Not included) for securing |
| appliance to the manufactured home ßoor. |
¥ | The appliance must be grounded to the |
| chassis of the manufactured home. Use a |
| No. 8 or heavier copper wire at least 18Ó in |
| length. |
¥ | The structural integrity of the manufactured |
| home ßoor, walls, ceiling and roof must be |
| maintained. |
¥ | A manufactured (mobile) home installation |
| must conform with the Manufactured Home |
| Construction and Safety Standard, Title 24 |
| CFR, Part 3280, or, when such a |
| is not applicable, the Standard for Manufac- |
| tured Home Installations, ANSI / NCSBCS |
7.Are below grade penetrations of the gas line allowed?
8.Is concealed gas piping allowed?
9.SpeciÞ c requirements of concealed Þ t- tings?
10.Is rigid pipe to appliance required?
11.Allowed piping materials?
13.May the
14.Rooms where the installation is not allowed?
In the absence of local codes, installation should conform to National Fuel Gas Code, ANSI Z223.1 / NFPA
VENT TERMINATION CLEARANCES
Vertical Vent Termination Clearances
TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS
Horizontal Overhang
These instructions should be used as a guideline and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code
Horizontal Vent Termination Clearances
The horizontal vent termination must have a minimum of 3" (76 mm) clearance to any overhead combustible projection of 2 1/2" (64
mm)or less. See Figure 4. For projections exceeding 2 1/2" (64 mm), For additional vent location restrictions refer to Figure 5.
Horizontal Vent Termination Clearances
Combustible Projection 2 1/2 inches or less in length
Combustible Projection greater than 2 1/2 inches in length
Ventilated
Soffit Unventilated
Soffit
A225.1, or standard for Gas equipped |
Recreational Vehicles and Mobile Housing, |
CSA Z240.4. |
QUESTIONS TO ASK LOCAL BUILDING OFFICIAL
This appliance must be installed per manu- facturersÕ instructions.
Installations must conform to appropriate
2 FT MIN.
Vent Termination
Storm Collar
Flashing
Concentric
Vent Pipe
2 FT | Vertical |
MIN. | Wall |
| |
Lowest |
|
Discharge |
|
Opening |
|
H* | X |
| |
| 12 |
Roof Pitch is X/12 |
1 inch (25.4 mm) Minimum Clearance to Combustibles
*H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT
|
|
|
|
|
|
| 3" | 3" | |
18" | 12" |
|
| (76 mm) | |||||
|
| (76 m | |||||||
(457 mm) | (305 mm) |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
Horizontal Termination Kit
1"
(25 m
Note - See vent manufacturer's instructions for recess allowances, into exterior walls for the horizontal termi-
local codes and applicable state and federal requirements. Familiarity with these requirements before installation is essential. Some important considerations to discuss with local building ofÞcials include:
1.Applicable codes (i.e. Uniform Mechanical Code, State or Regional Gas Codes, National Fuel Gas Code)
2.Local amendments
3.Recognized testing lab:
4.Is a permit required - cost?
5.In some states or municipalities, a licensed gas Þtter or plumber may be required to install this appliance. Check with your local building ofÞcial for requirements in your area (i.e. Is a license required for installation of gas supply line)?
6.Maximum amount of gas pipe without a pressure test - type of test required?
6
The vent/air intake termination clearances above the high side of an angled roof is as
follows: |
|
|
Roof Pitch ................. | Feet | Meters |
Flat to 6/12 ................ | 1.0 | 0.3 |
6/12 to 7/12............... | 1.25 | 0.38 |
7/12 to 8/12............... | 1.5 | 0.46 |
8/12 to 9/12............... | 2.0 | 0.61 |
9/12 to 10/12............. | 2.5 | 0.76 |
10/12 to 11/12........... | 3.25 | 0.99 |
11/12 to 12/12........... | 4.0 | 1.22 |
12/12 to 14/12........... | 5.0 | 1.52 |
14/12 to 16/12........... | 6.0 | 1.83 |
16/12 to 18/12........... | 7.0 | 2.13 |
18/12 to 20/12........... | 7.5 | 2.29 |
21/12 to 21/12........... | 8.0 | 2.44 |
Figure 3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
nation caps.
Figure 4 | Side Elevation View |