NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5
When Planning for the installation of the fire-
place, the framing height must be increased
from 46-1/2 inches to 47-1/4 inches, when
installing the drain pan. An additional space
below the fireplace will also be required to
plumb a drain line.
Step 1. Seal all joints, gaps and corners around
the bottom of the drain pan before positioning
the fireplace on its location (Figure 3 ).
Step 2. On the exposed drain hole, install a PVC
threaded coupling reducer, 3/4" x 1/2" going
from the top of the pan down through the hole.
Apply a silicone-based sealant around the base
and threads before installation.
Step 3. Holding the reducer coupling with a
wrench, thread a 3/4", 90 degree, PVC elbow to
the reducer until it is tight to the metal.
Step 4. Add additional piping to route the drain
to an appropriate location.
Note: To assure proper drainage, the fireplace
must be installed on a leveled surface.
CLEArANCES
Minimum clearance to combustibles for the
fireplace is as follows; sides and back – 1/2"
(13mm), combustible floor – 0" (0mm), adja-
cent wall 6" (152mm), ceiling – 50" (1270mm).
Refer to Figure 4 on this page and Figure 18
on page 13 for more detail.
Note: Clearance behind the nailing flange for
both fireplace models is 1/2" (13mm).
Note: Adjacent wall considerations are for an
adjacent wall to only a single side. Walls should
not be placed at the minimum distance on both
sides of the fireplace. Allow at least 4 feet on
one side of the fireplace.
Figure 4
Figure 3
47 1/4
drain Connector detail
threaded
reducer
3/4 x 1/2
(PVC)
threaded
Elbow 3/4
@ 90°
(PVC)
1/2” Airspace Clearance
to Sides And Back
No Material Within
the Face Opening
Noncombustables
May Overlap the Face
Combustable Materials
Allowed Flush With
the Face Front
No Combustables
Below the top Spacers
Noncombustable
Material Only
Only
Noncombustable
Material May
Overlap the
top Face
do NOt Overlap
Material Within
the Face Opening
1/2”
Airspace
Clearance
to Back
tOP VIEW
SIdE VIEW
5”
Combustible Material
May Overlap the
Face Bottom up to 2”
Below the Face Opening
No Material
Allowed in
this Area
1/2” Clearance
1/2” Airspace Clearance
to Sides And Back
Nailing Flange May
Make direct Contact
With Combustible
Framing