NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
8
PROCEDURE FOR REMOVING STANDARD
GLASS DOOR ASSEMBLY
Burner Flame Appearance
BURNER ADJUSTMENT
Flame Appearance and Sooting
Proper flame appearance is a flame which is blue at the base and becomes
yellow/orange in the top of the flame. When the insert is first lit, the entire
flame may be blue and will graduallay turn yellow/orange during the first
6-8 minutes of operation. If after 6-8 minutes the flame stays blue, or if
the flame is orange with evidence of sooting (black tip), the air shutter
may require adjustment.
An appliance operated with an air shutter opening that is too large will
exhibit flames that are blue and transparent. These weak, blue and
transparent flames are termed anemic. If the air shutter opening is too
small, sooting may develop.
Sooting is indicated by black puffs developing at the tips of very long
orange flames. Sooting results in black deposits forming on the logs,
appliance inside surfaces and on exterior sur faces adjacent to the
vent termination. Sooting is caused by incomplete combustion in the
flames and lack of combustion air entering the air shutter opening. To
achieve a warm yellow to orange flame that does not soot, the shutter
opening must be adjusted between these two extremes.
No smoke or soot should be present. Reposition the logs if flames
impinge on any of them. If the logs are properly positioned and
sooting conditions exist, the air shutter opening on the main burner
tube should be adjusted.
Figure 13 EBVI25 Shown
Release latch on
each side (below door)
Remove the front door assembly from insert as follows:
1) Open the two latches below the glass door as shown in Figures
11 & 12.

Figure 11

2) Swing the bottom of the door outward (see Figure 12) and lift it
off of firebox top. Set door aside in a safe place.

Figure 12

Latches
Glass Door
Top
Flange
Door
Frame
Firebox Floor
Bottom Vee-flange
Door Frame
Glass Door
WARNING
Handle glass door with extreme care! The glass door assembly is susceptible to damage. Do not scratch while handling or while reinstalling.
WARNING
Never operate unit without the front glass door panel in place and secure.
IMPORTANT
Ensure that the front glass panel is in place and sealed during adjustment.