5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
• Ahard wired carbon monoxide detector
with an alarm and battery back-up must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified.
• Ametalorplasticidenticationplatemust
be permanently mounted to the exterior of
the building at a minimum height of eight (8)
feet above grade and be directly in line with
the horizontal termination. The sign must
read, in print size no less than one-half (1/2)
inch in size, GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
NEW YORK CITY, NEW YORK (MEA)Installation of these fireplaces are approved
for installation in New York City in the US state
of New York.
COLD CLIMATE INSULATIONFor cold climate installations, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter
the room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level. Gas line holes and other open-
ings should be caulked or stuffed with unfaced
fiberglass insulation.
If the fireplace is being installed on a cement
slab in cold climates, a sheet of plywood or
other raised platform can be placed underneath
to prevent conduction of cold transferring to
the fireplace and into the room. It also helps to
sheetrock inside surfaces and tape for maximum
air tightness and caulk firestops.
MANUFACTURED HOME REQUIREMENTSThis appliance may be installed in an aftermarket
permanently located, manufactured home and
must be installed in accordance with the manu-
facturer's instructions and the Manufactured
Home Construction and Safety Standard, Title
24 CFR, Part 3280, in the United States, or the
Standard for Installation in Mobile Homes, CAN/
CSA Z240 MH Series, in Canada.
Cet appareil peut être installé cómme du matéri-
el d'origine dans une maison préfabriquée (É.U.
seulement) ou mobile et doit être installé selon
les instructions du fabricant et conformément
à la norme Manufactured Home Constructions
and Safety, Title 24 CFR, Part 3200 aux Unis ou
à la norme Can/CSA-Z240 Série MM, Maisons
mobiles au Canada.
Figure 3 - Typical LocationsNOITACILPPA TNEVPOT
APPLICATION
TOP VENT
TNEVPOT NOITACILPPA
RECESSED
INSTALLATION
TOP VENT
APPLICATION
NOITACILPPA
TNEVPOT
NOITACILPPA
TNEVPOT
HORIZONTAL VENT
(Top Vent Application)
VERTICAL VENT
(Top Vent Application)
Note: When the unit is installed with one
side flush with a wall, the wall on the other
side of the unit must not extend beyond the
front edge of the unit.
LOCATIONIn selecting the location, the aesthetic and
functional use of the appliance are primary
concerns. However, vent system routing to
the exterior and access to the fuel supply are
also important.
Due to high temperatures, the appliance
should be located out of traffic and away from
furniture and draperies (Figure 3).
En raison des températures élevées, l’appareil
devrait être installé dans un endroit où il y a
peu de circulation et loin du mobilier et des
tentures (Figure 3).
The location should also be free of electrical,
plumbing or other heating/air conditioning
ducting.
These direct-vent appliances are uniquely
suited for installations requiring a utility shelf
positioned directly above the fireplace. Utility
shelves like these are commonly used for locat-
ing television sets and decorative plants.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
Cet appareil doit être utilisé uniquement avec le
type de gaz indiqué sur la plaque signalétique.
Cet appareil ne peut être converti à d'autres gaz,
sauf si une trousse de conversion est utilisée.
CAUTION: Ensure that the cross mem-bers are not cut or weakened during installation. The structural integrity of the manufactured home floor, wall, and ceiling / roof must be maintained. CAUTION: This appliance must be ground-ed to the chassis of the manufactured home in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI / NFPA 70 - latest edition or the Canadian Electrical Code CSA C22.1 - latest edition.