Note: Safety strips are not required when fire- place rests on a noncombustible surface.
Note: Install the hearth extension only as illus- trated (see Figures 41 and 42 ).
FIREPLACE SPECIFICATIONS
51 ¹⁄₈"
(1299mm)
The safety strips should extend from front of the fireplace at least 1 ¹⁄₂" and should extend to be at least flush with the sides. In the event a wooden support is used to elevate the fireplace above the floor, a “Z” type safety strip should be fabricated and used to protect the front surface of the wood support as well as the floor beneath the hearth extension (Figures 7 and 8 ). The safety strips should be tacked down to prevent possible movement.
Note: The “Z” type safety strip is not supplied.
6¹⁵⁄₁₆" (176mm)
24¹⁄₁₆"
(611mm)
8 ⁵⁄₈"
(219mm)
4 ³⁄₁₆" (106mm)
42 ³⁄₄" (1086mm)
52 ¹⁄₄" (1327mm)
Front View
¹⁄₂"
(13mm)
39 ¹¹⁄₁₆"
(1008mm)
4¹⁄₂"
114mm)
1⁹⁄₁₆"
(40mm)
6
1¹⁄₂"
(38mm)
Metal Safety Strips with ¹⁄₂" (13mm) Min. Overlap
Figure 7
Blocking
Special “Z” Metal Safety
2"Strips with ¹⁄₂" (13mm) Min.
(51mm) Overlap
Figure 8
Step 3. Refer to fireplace drawings and speci- fications on pages 6 and 7 for framing dimen- sions and details. Frame appliance enclosure as illustrated in Figures 10 through 13 on page 7.
IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS (FIGURE 9 ) BE REMOVED OR MODIFIED, NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPAC- ERS. THE HEADER MAY BE IN DIRECT CON- TACT WITH THE TOP SPACERS BUT MAY NOT BE SUPPORTED BY THEM.
25 ¹⁄₈"
¹⁄₂" (638mm) (13mm)
9¹⁵⁄₁₆"
(252mm) | 44 ⁵⁄₈" |
| (1133mm) |
39 ¹¹⁄₁₆" | 49 ⁵⁄₈" |
(1008mm) | |
| (1260mm) |
11" | 12 ⁷⁄₁₆" |
(316mm) | |
(279mm) | 5 ¹⁄₁₆" |
| |
| (129mm) |
1 ⁹⁄₁₆" |
| 11 ⁵⁄₁₆" | |||
(40mm) |
| (287mm) | |||
|
|
| Side View (Left) | ||
|
|
|
| 31" (788mm) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
1 ¹⁄₄"
(32mm)
9 ³⁄₄"
(248mm)Drain 11 ⁵⁄₁₆"
Plug (287mm)
¹⁄₂" (13mm)
Top View
Figure 9