What are the INSTALLER settings?

The INSTALLER SETTINGS are setup during the initial installation. They tell the thermostat how to function with your heating or cooling equipment. The following is a brief overview and discussion of these settings.

INSTALLER SETTINGS

SYSTEM SETUP

GAS

RESIDUAL COOL

60

LOW BALANCE

45˚F

HIGH BALANCE

95˚F

HOME

SELECT

*

INSTALLER SETTINGS

AUTOCHANGEOVER ON

EER

ON

DEADBAND

3˚F

HUMIDITROL

OFF

HOME

SELECT

INSTALLER SETTINGS

SECURITYOFF CONTACT INFO

SERVICE INT

REMINDERRUN

MAIN MENU

SELECT

INSTALLER SETTINGS

CONTACT INFO

 

SERVICE INT

 

REMINDER

RUN

TEMP OFFSET

0.0°F

MAIN MENU

SELECT

*DEADBAND is displayed only when AUTOCHANGEOVER is ON.

SYSTEM SETUP

SYSTEM SETUP

 

 

 

Choose the system component that the thermostat will control.

FURNACE

 

With the 81M26, either a furnace or a single-stage heat pump (with no auxiliary heat)

HEAT PUMP

 

can be used. If FURNACE is selected, then either a GAS/OIL or ELECTRIC furnace

 

 

 

can be used.

INSTALL MENU

SELECT

 

 

 

 

1st STAGE HEATING

1ST STAGE HEATING

 

 

 

With the 81M27, either a GAS/OIL or ELECTRIC furnace can be used.

 

GAS / OIL

 

 

 

 

 

ELECTRIC

 

 

INSTALL MENU

SELECT

 

 

 

 

 

21

Page 21
Image 21