IMPORTANT WARNINGS

CAUTION: Read this manual thoroughly before starting installation. For your safety, follow the installation, op- eration and maintenance instructions exactly without deviation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. If this appliance is not properly installed, a house fire may result. Contact local building or fire officials about restrictions and installation inspection in your area.

1.If utilizing an older chimney, it must be inspected for adequate serviceability. Refer to the heading Chimney Inspection on page 6.

2.Install only in masonry fireplaces, built to UBC chapter 37 standards or listed factory built fire- places.

3.The minimum clearances must be maintained for all combustible surfaces and materials including; furniture, carpet, drapes, clothing, wood, papers, etc. Do not store firewood within this clearance space.

4.This appliance requires a non-combustible heat resistant approved fireplace hearth or hearth ex- tension. This protected area must extend a mini- mum of 16" to the front of the fuel door opening and 8" beyond both sides of the fuel door opening (see floor protection on page 5 for additional infor- mation).

5.Minimum ceiling height must be 7 feet (measured from base of appliance to ceiling).

6.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE CONNECTED TO ANOTHER APPLIANCE.

7.Do not connect this appliance to air ducts or any air distribution system.

8.Do not install appliance in a sleeping room.

9.PREVENT CREOSOTE FIRE: Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup may occur rapidly. Inspect chimney connector and chimney twice monthly and clean if necessary. Using green or inadequately seasoned wood can greatly increase creosote buildup. Use dry wood to minimize creosote buildup.

10.USE SOLID WOOD FUEL ONLY: This appliance is approved for burning dry seasoned natural wood only.

11.Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use.

12.DO NOT OVERFIRE: If heater or chimney con- nector glows, you are overfiring. Overfiring this ap- pliance could cause a house fire. Overfiring is a condition where the appliance is operated at tem- peratures above its design capabilities. Overfiring can be caused by improper installation, improper

PAGE 2

operation, lack of maintenance or improper fuel usage. Damage caused from overfiring is NOT covered under the manufacturers limited warranty.

13.NEVER LEAVE AN UNATTENDED FIREPLACE INSERT BURNING ON HIGH. Operation of the fireplace insert with the primary air control at its highest burn rate setting for extended periods can cause dangerous overfiring conditions. The pri- mary air control should only be positioned at the highest setting during start-up procedures and for short durations. When leaving the fireplace insert unattended ensure that the primary air control is set to the low or medium low range.

14.Use a metal container with a tight fitting lid to dis- pose of ashes.

15.Burning any kind of fuel uses oxygen from the dwelling. Be sure that you allow an adequate source of fresh air into the room where the fire- place insert is operating (see Ventilation on page 6).

16.CAUTION: HOT WHILE IN OPERATION. An ap- pliance hot enough to warm your home can se- verely burn anyone touching it. Keep children, clothing and furniture away. Contact may cause skin burns. Do not let children touch the appliance. Train them to stay a safe distance from the unit.

17.Once the fire is established, never burn the appli- ance with the bypass open, except when refueling the appliance.

18.CATALYTIC COMBUSTOR: Do not operate this appliance without the catalytic combustor assembly (this consists of ceramics, gasket and a housing) properly installed. Burning of metal foils, coal, plas- tic garbage, diesel oil and sulfur will make the catalyst in the combustor inactive. The combustor is fragile; handle carefully. The performance of the catalytic device or its durability has not been evalu- ated as part of the certification.

19.Build fires directly upon the brick hearth inside the fireplace insert. Do not use grates, irons or any other method to elevate the fire.

20.SAVE THESE INSTRUCTIONS.

21.See the listing label located on the back of fire- place (or see Safety/Listing Label on page 26).

Page 2
Image 2
Lennox International Inc BV4000C operation manual Important Warnings

BV4000C specifications

Lennox International Inc has long been a leader in manufacturing high-efficiency heating, cooling, and refrigeration systems. Among its innovative product line is the Lennox BV4000C, a powerful and reliable commercial ventilation system designed to enhance indoor air quality and optimize energy efficiency. The BV4000C is engineered for use in various commercial settings, providing superior performance and durability.

One of the standout features of the BV4000C is its exceptional air capacity. Capable of delivering substantial airflow, it is ideally suited for larger commercial spaces that require effective ventilation. The unit is designed with advanced fan technology that ensures quiet operation while maintaining high efficiency. This reduces noise pollution in busy environments, making it a great choice for restaurants, offices, and retail establishments.

Energy efficiency is a top priority for the BV4000C, which is equipped with cutting-edge inverter-driven scroll compressors. These compressors automatically adjust their speed based on the demand for cooling or heating, leading to substantial energy savings. With its high SEER (Seasonal Energy Efficiency Ratio) rating, the BV4000C significantly lowers energy consumption without sacrificing comfort.

The BV4000C features innovative control technologies that streamline operation and improve user experience. The integrated smart thermostat allows for precise temperature control and can be easily programmed to meet the specific needs of any commercial setting. Additionally, it supports remote monitoring and control capabilities through mobile applications, ensuring that operators can manage their HVAC systems from anywhere.

Durability and reliability are critical for commercial HVAC systems, and the BV4000C does not disappoint. Constructed with high-quality materials, it is designed to withstand rigorous operational conditions and offers a long lifespan. The unit's robust build minimizes maintenance requirements, further enhancing its appeal for business owners seeking dependable solutions.

Safety is also a key consideration in the design of the BV4000C. It incorporates advanced safety features such as built-in surge protection, ensuring the unit operates safely even in variable electrical environments.

In summary, the Lennox BV4000C is a state-of-the-art commercial ventilation system that excels in efficiency, performance, and reliability. Its advanced technologies, versatile features, and commitment to energy savings make it an invaluable addition to any commercial property. Whether for cooling, heating, or ventilation, the BV4000C serves as an exemplary choice for businesses looking to enhance their indoor environment while reducing operational costs.