FIREPLACE INSTALLATION

BV4000C MINIMUM FIREPLACE DIMENSIONS

 

Approx. minimum

Height: 21”

 

dimensions into fireplace

Width: 22 ½”

 

 

Depth: 16”

CATALYTIC TEMPERATURE PROBE

Install temperature probe prior to installing insert. To install the Catalytic Temperature Probe locate the plug on the top, right-hand side of the bypass control rod. Remove the plug, install the sleeve, and place probe in sleeve. It may be necessary to bend the flange on the plug so it won't interfere with the probe temperature indicator.

The Catalytic Temperature Probe is provided so you can monitor the temperature of your Catalytic Com- bustor. Once you have established a fire and the Catalytic Temperature Probe indicates the tempera- ture of your Catalytic Combustor is between 500° - 600° F (approximately 20 - 25 minutes) close the By- pass Damper Control. Depending on the type and size of the fuel load as well as the length of time the stove has been burning, your Catalytic Combustor should operate between 1000 - 1800° F.