Troubleshooting Tips (Continued)

If . . .

Then . . .

 

 

ait" is displayed

Compressor minimum−off timer is activated.

on the screen.

Wait up to five minutes for the compressor

 

to turn on.

 

 

Fan does not turn on

Check Installer Set−Up 0180: Fan Control in

in a call for heat

Heating*. Make sure Electric Heat option is

(electric furnaces

selected.

only)

 

 

 

Both heating and

Check Installer Set−Up Number 170: Heating

cooling systems are

and/or Cooling Type*. Make sure the setting

operating at the

matches the installed heating and/or cooling

same time.

system.

 

Check to ensure that bare portions of wires

 

are not touching.

 

 

Heating is running in

Check Installer Set−Up Number 170: Heating

Cool mode.

and/or Cooling Type*. Make sure the setting

 

matches the installed heating and/or cooling

 

system.

 

 

Heating system

Check Installer Set−Up Number 170: Heating

does not turn off and

and/or Cooling Type*. Make sure the setting

the heat tempera-

matches the installed heating and/or cooling

ture setting is set

system.

below the room tem-

 

perature ("Heat On"

 

is not shown in dis-

 

play.)

 

 

 

Red LED is lit in the

A system monitor is wired to the thermostat

upper right corner of

L terminal. Refer to suggestions given in

the thermostat when

Heating or Cooling System Does Not Turn

the system monitor

On sections in this table.

detects a possible

 

problem.

 

 

 

*Refer to Installation Instructions for access to Installer Set−Up pro- cedures.