Removing and replacing a FRU

1070 Fingerprint board

Note: Only for the models with fingerprint function.

For access, remove following FRUs, in order:

v“1010 Battery pack” on page 77

v“1050 Keyboard” on page 83

v“1060 Upper case” on page 86

Before removing fingerprint board, remove the two screws to remove the fingerprint bracket.

1

1

2

Step

Screw (quantity)

Torque

 

 

 

 

M2 × 3.5 mm, nylon-coated (2)

0.196 Nm

 

 

(2 kgfcm)

 

 

 

Remove the fingerprint FPC and remove the fingerprint board.