Removing and replacing a FRU
1070 Fingerprint board
Note: Only for the models with fingerprint function.
For access, remove following FRUs, in order:
v“1010 Battery pack” on page 77
v“1050 Keyboard” on page 83
v“1060 Upper case” on page 86
Before removing fingerprint board, remove the two screws to remove the fingerprint bracket.
1 |
1 |
2 |
Step | Screw (quantity) | Torque |
|
|
|
| M2 × 3.5 mm, | 0.196 Nm |
|
| (2 kgfcm) |
|
|
|
Remove the fingerprint FPC and remove the fingerprint board.