Operating Angle Type Service Valve:

Operating Angle Type Service Valve:

1.Remove stem cap with an appropriately sized wrench.

2.Use a service wrench with a hex−head extension (3/16" for liquid line valve sizes and 5/16" for vapor line valve sizes) to back the stem out counterclockwise as far as it will go.

SERVICE PORT CAP

 

SERVICE PORT CORE

 

 

 

(VALVE STEM SHOWN

TO INDOOR

 

CLOSED) INSERT HEX

UNIT

(VALVE STEM SHOWN OPEN)

WRENCH HERE

 

INSERT HEX WRENCH HERE

 

SERVICE PORT

STEM CAP

CORE

 

TO OUTDOOR UNIT

 

ANGLE−TYPE SERVICE VALVE

ANGLE−TYPE SERVICE VALVE

(FRONT−SEATED CLOSED)

(BACK−SEATED OPENED)

 

When service valve is OPEN, the service port is

WHEN SERVICE VALVE IS CLOSED, THE SERVICE PORT IS OPEN

open to linE set, indoor and outdoor unit.

TO THE LINE SET AND INDOOR UNIT.

Operating Ball Type Service Valve:

1.Remove stem cap with an appropriately sized wrench.

2.Use an appropriately sized wrenched to open. To open valve, rotate stem counterclockwise 90°. To close rotate stem clockwise 90°.

To Access Service Port:

A service port cap protects the service port core from contamination and serves as the primary leak seal.

1.Remove service port cap with an appropriately sized wrench.

2.Connect gauge set to service port.

3.When testing is completed, replace service port cap and tighten as follows:

TO OPEN ROTATE STEM COUNTERCLOCKWISE 90°.

TO CLOSE ROTATE STEM CLOCKWISE 90°.

TO INDOOR UNIT

BALL (SHOWN CLOSED)

VALVE

STEM

SWith torque wrench: Finger tighten and torque cap per table 1.

SWithout torque wrench: Finger tighten and use an appropriately sized wrench to turn an additional 1/6 turn clockwise.

Reinstall Stem Cap:

1/6 TURN

11 12 1

10 2

98 7 6 543

SERVICE PORT Operating Ball Type Service Valve:

SERVICE PORT

CORE

SERVICE PORT

CAP

TO OUTDOOR

UNIT

STEM CAP

Stem cap protects the valve stem from damage and serves as the primary seal. Replace the stem cap and tighten as follows:

 

 

 

 

 

1/12 TURN

S

With Torque Wrench: Finger tighten and

 

 

 

 

 

 

 

 

 

 

 

 

 

then torque cap per table 1.

 

11 12

1

 

 

 

 

 

 

 

 

S

Without Torque Wrench: Finger tight-

10

 

 

 

2

 

 

 

 

en and use an appropriately sized

9

 

 

 

 

3

 

 

 

 

 

 

wrench to turn an additional 1/12 turn

8

7

6

5

4

 

 

 

 

clockwise.

 

 

 

 

 

 

 

 

 

NOTE A label with specific torque requirements may be affixed to the stem cap. If the label is present, use the specified torque.

Figure 2. Angle and Ball Service Valves

Page 5

XC16 SERIES

Page 5
Image 5
Lenox Elite Series X16 Air Conditioner Units Operating Angle Type Service Valve, Operating Ball Type Service Valve