TABLE 13

Manifold Pressure Settings at all Altitudes

Model

Gas

0−2000 ft

2001−4500 ft.

4501−7500 ft

7501 − 10,000 ft

Line Pressure in.wg.

 

 

Input Size

 

 

 

 

 

Min

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

045

Nat

3.5

3.2

3.0

3.5

4.5

13.0

 

 

 

 

 

 

 

LP/propane

10.0

10.0

10.0

10.0

11.0

13.0

 

 

 

 

 

 

 

 

 

070

Nat

3.5

3.2

2.8

3.5

4.5

13.0

 

 

 

 

 

 

 

LP/propane

10.0

10.0

10.0

10.0

11.0

13.0

 

 

 

 

 

 

 

 

 

090

Nat

3.5

3.2

2.7

3.5

4.5

13.0

 

 

 

 

 

 

 

LP/propane

10.0

10

9.6

10.0

11.0

13.0

 

 

 

 

 

 

 

 

 

110

Nat

3.5

3.5

3.0

3.5

4.5

13.0

 

 

 

 

 

 

 

LP/propane

10.0

10.0

9.6

10.0

11.0

13.0

 

 

 

 

 

 

 

 

 

135

Nat

3.5

3.5

2.9

3.5

4.5

13.0

 

 

 

 

 

 

 

LP/propane

10.0

10.0

9.6

10.0

11.0

13.0

 

 

 

 

 

 

 

 

 

TABLE 14

Pressure Switch and Gas Conversion Kits at all Altitudes

 

 

 

 

High Altitude

Natural Gas to LP/Propane

LP/Propane to

Model

High Altitude Pressure Switch Kit

Natural Gas Burner

Natural Gas Burner

Burner Orifice Kit

 

 

 

Orifice Kit

Orifice Kit

Input Size

 

 

 

 

 

 

 

 

 

 

 

 

 

0−4500 ft

4501−7500 ft

7501 − 10,000 ft

7501 − 10,000 ft

0 − 7500 ft

7501 − 10,000 ft

0 − 7500 ft

 

 

 

 

 

 

 

 

045

 

80W52

80W51

 

 

 

 

 

 

 

 

 

 

 

 

070

 

80W52

80W51

 

 

 

 

 

 

 

 

 

 

 

 

090

No Change

80W52

80W51

73W37

70W89

76W15

73W81

 

 

 

 

 

 

 

 

110

 

80W57

80W52

 

 

 

 

 

 

 

 

 

 

 

 

135

 

80W52

80W51

 

 

 

 

 

 

 

 

 

 

 

 

NOTE − A natural to L.P. propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the conversion procedure.

Other Unit Adjustments

Primary and Secondary Limits

The primary limit is located on the heating compartment vestibule panel. The secondary limits (if equipped) are lo- cated in the blower compartment, attached to the back side of the blower. These auto reset limits are factory−set and re- quire no adjustment.

Flame Rollout Switches

These manually reset switches are located on the burner box.

Pressure Switch

The pressure switch is located in the heating compartment adjacent to the combustion air inducer. The switch checks for proper combustion air inducer operation before allow- ing ignition trial. The switch is factory−set and requires no adjustment.

Temperature Rise

After the furnace has been started, and supply and return

air temperatures have been allowed to stabilize, check the temperature rise. If necessary, adjust the blower speed to maintain the temperature rise within the range shown on the unit nameplate. Increase the blower speed to decrease the temperature. Decrease the blower speed to increase the temperature rise. Failure to adjust the temperature rise may cause erratic limit operation.

Fan Control

The heat fan−on time of 30 seconds is not adjustable. The heat fan−off delay (amount of time that the blower operates after the heat demand has been satisfied) may be adjusted by changing the jumper position across the five pins on the integrated control. The unit is shipped with a factory fan−off delay setting of 90 seconds. The fan−off delay affects com- fort and is adjustable to satisfy individual applications. Ad- just the fan−off delay to achieve a supply air temperature between 90° and 110°F at the moment that the blower is de−energized. Longer off delay settings provide lower re- turn air temperatures; shorter settings provide higher re- turn air temperatures. See figure 36.

Page 31

Page 31
Image 31
Lenox Lennox Merit Series Gas Furnace Upflow/Horizontal air discharge, ML180UHE Other Unit Adjustments

Lennox Merit Series Gas Furnace Upflow/Horizontal air discharge, ML180UHE specifications

The Lenox ML180UHE is a reliable and efficient gas furnace that falls within the Lennox Merit Series. This model is designed for upflow or horizontal air discharge, making it versatile for various installation requirements. With its robust construction and advanced technology, the ML180UHE is ideal for homeowners seeking a dependable heating solution that combines comfort and efficiency.

One of the main features of the ML180UHE is its impressive 80% Annual Fuel Utilization Efficiency (AFUE) rating. This efficiency means that 80 cents of every dollar spent on fuel is used to heat your home while minimizing waste. This furnace is equipped with a multi-speed blower motor that enhances the overall air circulation in your home, providing consistent temperatures and improved comfort.

The ML180UHE features a durable heat exchanger made of high-quality materials, which ensures longevity and reliable performance. The design of the heat exchanger maximizes heat transfer efficiency, allowing the furnace to quickly warm your home while also maintaining optimal efficiency levels throughout its lifespan.

Lennox has integrated advanced technologies into the ML180UHE to enhance its operation and user experience. The unit is compatible with a variety of thermostats, including Lennox's innovative iComfort S30 Smart Thermostat, allowing for easy temperature control and programming capabilities. This smart technology can learn your preferences, optimize energy usage, and enable remote access through a smartphone app.

In addition to its energy efficiency, the ML180UHE offers quiet operation, making it an excellent choice for residential environments. The well-insulated cabinet helps to reduce noise levels, providing a peaceful indoor atmosphere.

Installation and maintenance are simplified with the ML180UHE due to its compact design and accessible components. The furnace is designed to fit into tight spaces, allowing for flexible installation options. Regular maintenance is uncomplicated, ensuring that homeowners can keep the unit running at peak performance with minimal effort.

Overall, the Lennox ML180UHE gas furnace provides users with a reliable, efficient, and quiet heating solution. With its combination of advanced technology, durable design, and ease of use, it is an excellent choice for anyone looking to enhance the comfort of their home while optimizing energy consumption.