PLANNING YOUR INSTALLATION– Model CI2000HT

MODEL CI2000HT

COMBUSTIBLE WALL CLEARANCE – USA & Canada

WARNING: It is very important that you observe the minimum clearances.

There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first established for the stove itself and increased based on how much heat is transferred by each class of pipe.

Position the unit no closer than the minimum clearances to combustible materials. Check that no overhead cross members in the ceiling or roof will be cut. Reposition unit if necessary being careful not to move closer than the minimum clearances.

SINGLE WALL PIPE (Not approved for alcove instal- lations) Using single wall 24 MSG black or 25 MSG blued steel connector pipe with factory-built chimney listed to either UL 103HT or ULC S629.

Minimum Clearances (inches)

A. 18" / 457mm

D.

13" / 330mm

B. 32" / 813mm

E.

20" / 508mm

C. 27" / 686mm

F.

16" / 406mm

G. 35 3/16” / 894 mm (this is a reference dimension only)

DOUBLE WALL PIPE (For alcove installations, clearances "C" and "F" are not applicable) Use listed double wall chimney connector or Type L vent pipe to the top of the stove.

Minimum Clearances (Inches)

A. 14 1/2" / 368mm

D. 10" / 254mm

B. 28 1/2" / 724mm

E. 17" / 432mm

C. 18" / 457mm

F. 7" / 178mm

Minimum Ceiling Height for Single wall pipe and double wall pipe installations and Alcove Installations – 60" / 1524mm from floor to ceiling and 29" / 737mm from stove top to ceiling.

ALCOVE INSTALLATION CLEARANCES

Alcove Installations Require Double Wall Pipe Only Use listed double wall chimney connector or Type L vent pipe to the top of the stove.

Minimum Clearances (Inches)

A. 14 1/2" (368 mm)

D. 10" (254 mm)

B. 28 1/2" (724 mm)

E. 17" (432 mm)

C. N/A

F. N/A

Note: Alcove clearances cannot be reduced using wall protection. Maximum alcove depth must be no more than 48" (1220 mm).

Parallel & Alcove Installations

D A

BE

Corner Installation

C

G

F

PROTECTED WALL CLEARANCE

Some local codes will allow reduced clearances when the stove is installed adjacent to a protected wall system. The variance must be approved by your local building official. Normally, the protected wall system is defined as a non- combustible material with a minimum of 1" air space behind. Check your local building codes or with a qualified installer (Ref. NFPA 211).

PAGE 9