Step 6 cont'd Including 4-Zone Controller into Z-WaveTMNetwork:

Step 6 cont'd Including 4-Zone Controller into Z-WaveTMNetwork:

Programmer/Remote

Cat. No. RZCPG

NOTE: Programmer/Remote must be in close proximity to 4-Zone controller when including in the network.

Step 8 Device Association:

After inclusion process, you must associate the devices to the controllers. Refer to the Primary Programmer/Remote instruction sheet for complete details.

NOTE: One (1) Z-WaveTMdevice can be associated to multiple controllers (up to five (5) controllers maximum).

NOTE: If using a non-Leviton Programmer/Remote, refer to the Programmer/Remote instruction sheet for associating a device.

Step 9 4-Zone Controller Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

TROUBLESHOOTING

 

NOTES

 

 

 

Locator LED on controller does not turn ON

-Circuit breaker or fuse has tripped.

-If 4-Zone controller is powered up and LED does not turn ON, check wiring.

Zone Controller does not operate lights

-Check association.

-Ensure that controller was properly updated.

If LED turns solid red

-Check association.

-Ensure that each device in the network is with in 70 ft (21 m) of another device.

Step 7 Excluding 4-Zone Controller from Step 8 Device Association: Z-WaveTMNetwork:

A)If using a Leviton Z-WaveTMProgrammer/Remote, Cat. No. RZCPG, press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Press the center button to select Network. Scroll down to <Exclude Node> and press the center button.

B)If using RZCPG Programmer/Remote, you will be prompted to place 4-Zone controller into programming mode.

C)To access Program mode, press and hold the left side of buttons 1 and 3 (refer to figure). Wait 5 seconds until the LED turns Amber. Release the buttons and the LED will blink Amber. You are now in Programming mode.

NOTE: If the LED on the 4-Zone controller turns solid Red while excluding, there has been a communication error.

D)While standing close to the 4-Zone controller (approximately 2-5 ft.), press the center button on the Programmer/Remote to <Exclude> device in the network.

Factory Default:

If your 4-Zone controller is not responding, or you are unable to control

Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.

Step 10 Restore Power:

Restore power at circuit breaker or fuse.

 

Installation is complete.

Push

 

 

OPERATION

 

Buttons

 

 

 

 

 

Push Button (Default settings)

Turn ON from OFF position:

Press left side of button – Turns all lights in

Zone/Area ON, LED turns ON.

LED will blink until Zone/Area is ON.

Turn OFF from ON position:

Press right side of button – Turns all lights in

Zone/Area OFF, LED turns OFF.

Dim/Bright:

For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.ViziaRF.com

U.S. & Foreign Patents Pending

Copyright© 2006 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

FCC COMPLIANCE STATEMENT

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by

it after you have tried to Include/Exclude it multiple times, it may be necessary to reset the 4-Zone controller to its original factory settings. To accomplish this, proceed as follows:

On the 4-Zone controller (refer to figure), press and hold the left side of buttons 1 and 3. Wait

approximately 5 seconds until the locator LED

turns Amber and then turns solid Red. Release the buttons. The 4-Zone controller is now reset. Once the controller is reset, it will be necessary to Re-Include it to a network before it can be used.

CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION

PROCEDURE MUST STILL BE FOLLOWED TO

REMOVE THE DEVICE FROM THE PRIMARY CONTROLLER’S INFORMATION TABLE. FAILURE

TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO RESPOND TO SOME DEVICES.

Press left side of Dim/Bright button - Lights in last activated Zone/Area will dim.

Press right side of Dim/Bright button - Lights in last activated Zone/Area will brighten.

NOTE: Controller will only Dim/Bright devices located within the Radio Frequency range.

NOTE: LED will be lit Green if any one load in the associated Area is ON. LED will be OFF when all loads are turned OFF.

If there is a power outage, when the power is restored, the lights will return to the last setting before the power interruption.

Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.

Locator Dim/Bright

LED Button

one or more of the following measures:

Reorient or relocate the receiving Antenna.

Increase the separation between the equipment and the receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/tv technician for help.

DI-000-RZCZ4-00A-X1

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

Page 2
Image 2
Leviton RZCZ1 Troubleshooting, Operation, Fcc Compliance Statement, Device Association, 4-Zone Controller Mounting