Electrical specifications

Printer model

X264 MFP low voltage models*

X264 MFP high voltage models

X360 MFP low voltage models

X360 MFP high voltage models

X460 MFP low voltage models

X460 MFP high voltage models

Electrical specification

100-110 V (Japan) at 50-60 Hz, nominal 100-127 V at 50-60 Hz, nominal 90-110 V (Japan), extreme

90 -135 V, extreme

198-254 V, extreme

220-240 V at 50-60 Hz, nominal

100-110 V (Japan) at 50-60 Hz, nominal 100-127 V at 50-60 Hz, nominal 90-110 V (Japan), extreme

90 -135 V, extreme

198-254 V, exteme

220-240 V at 50-60 Hz, nominal

90-137 V, extreme

100-127 V at 50-60 Hz, nominal

198-259 V, extreme

220-240 V at 50-60 Hz, nominal (not available in all countries)

* Using a 220–110 power converter with 110 V printer is not recommended.

Warning—Potential Damage: Lexmark recommends that you do not use voltage converters with printers.

Power requirements

This lists the nominal average power requirements (including fuser power).

Printing states

Average power while printing continuously

X264 MFP

X360 MFP

X460 MFP

1-sided (simplex)

2-sided (duplex)

440W

275W

480W

300W

540W

340W

Average power while idle

Power Saver on

Ready mode

Max current while printing

14W

20W

16W

22W

25W

45W

100V

120V

230V

Copying continuously Scanning continuously

8.6A

7.6A

3.7A

440W

29W

8.6A

7.6A

3.7A

440W

32W

8.6A

7.6A

3.7A

560W

55W

Printer specifications

18

Page 18
Image 18
Lexmark X364DN/DW manual Electrical specifications, Power requirements