Chapter 7 Buffer read/write instructions
7 - 8
7.2.2 RPUT instructions
RPUT FUN(233) RPUT Applicable CPU
K200S
K300S
K1000S
Available devices Flag
Instructions M P K L F T C S D #D Integer Steps Error
(F110) Zero
(F111) Carry
(F112)
sl ¡
st ¡
S ¡
D ¡ ¡ ¡ ¡* ¡ ¡ ¡ ¡
n ¡ ¡
RPUT
SS ¡ ¡ ¡ ¡* ¡ ¡ ¡ ¡
13 ¡
Operand setting
Upper
byte Type of remote special function
module
sl Lower
byte Slot number of Fnet module of
self-station
D Start address of buffer memory
of A/D module of remote
station
Upper
byte Slot number of remote special
function module
st Lower
byte Station number of Fnet remote
module
n Number of words to be read
S Start address of device at which source
data is stored (self-station) SS Device at which the link status
is stored
* Available only when do not use computer link module or data link module
1) Functions
- Write the data of n words which start at the device specified as S to the block which
begin with the address specified as D of buffer memory inside the special function
module of remote station. (station number & slot number is specified as st) through the
Fnet communication module. Then stores the link status into the device specified as SS
of self-station.
RPUT sl st S D n SS
Input
condition