3. TECHNICAL BRIEF
3.4 Power ON/OFF
KS360 series Power State : Defined 3cases as follow
]
]
Remote Power On
RPWRON_EN
R223
RPWRON
2K
R225  | 100K  | 
330K  | R219  | 
R221
3.3M
1 2 3
C226
10u
6 5 4
2V0_VRTC  | 
  | END  | |
2K  | R220  | 
  | 
  | 
  | PWRON  | R222  | 
  | 
  | END_KEY  | 
  | |
  | 
  | 
  | |
  | 
  | 10K  | 
  | 
  | 
  | 100K  | R224  | 
  | EMX18  | 
  | 
  | 
  | Q201  | 
  | 
  | 
END_KEY_IN
KEY_COL7
KEY_ROW6
END_KEY_IN
Figure 6. Remote power on and End-key  power on circuit.
Input ON is a 
To support Remote power on function for factory mass production, applied an BJT as following figure. As monitoring the RPWRON and Key matrix KEY_COL7 & KEY_ROW6, KS360 series system recognize whether remote power on or 
LGE Internal Use Only  | - 32 -  | Copyright © 2008 LG Electronics. Inc. All right reserved.  | 
  | 
  | Only for training and service purposes  |