Part 3 ELECTRICAL CONNECTIONS

Part 3 ELECTRICAL CONNECTIONS

3ELECTRICAL CONNECTION REQUIREMENTS

This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI/NFPA NO. 70 - latest edition.

All wiring should conform to Local and NEC. This range requires a single-phase, 3 wire, A.C 120/208V or 120/240V 60Hz electrical system. Use only a 3-conductor or a 4-conductor UL-listed range cord with closed- loop terminals, open-end spade lugs with upturned ends or similar terminations. DO NOT install the power cord without a strain relief.

A range cord rated at 40 amps with 120/240 minimum volt range is required. If a 50 amp range cord is used, it should be marked for use with 138” diameter connection openings.

This appliance may be connected by means of conduit or power cord. If conduit is being used, go to page 7 3 wire conduit connections or page 8 for 4 wire conduit connections.

4CONNECT RANGE CORD

The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block will then be accessible.

FIGURE 4

The Cord/Conduit connection plate is used for the installation of power cord or conduit. For power cord, install it with the connection plate as INSTALLED. For conduit, remove the connection plate located below the rear of the drawer body and use the conduit hole (11/8”) instead of power cord hole (13/8”).

(Refer to Figure 5 and 6.)

ENGLISH

3ELECTRICAL CONNECTION REQUIREMENTS WARNING

New branch-circuit installations (1996 NEC) for mobile homes, recreational vehicles, and installations where local codes do not allow grounding through the neutral wire require a 4-conductor UL listed range cord or 4 wire conduit connection.

Specified power-supply-cord kit rating

Range rating, watts

Specified rating

Diameter (inches) of Range

connection Opening

 

 

of power-supply-

 

 

 

 

120/240 volts

120/208 volts

Power cord

Conduit

cord kit, amperes

3-wire

3-wire

 

 

 

 

 

 

 

 

8,750 - 16,500

7,801 - 12,500

40 or 50A

13/8

11/8

16,501 - 22,500

12,501 - 18,500

50

13/8

11/8

 

 

 

 

 

3, 4 - Wire electrical wall Receptacle

4 Wire receptacle (14-50R)

3 Wire receptacle (10-50R)