LG Electronics LRE3012S wire connection with a power supply cord, wire connection conduit

Models: LRE3012S

1 11
Download 11 pages 35.82 Kb
Page 7
Image 7
 4-wire connection with a power supply cord

Part 3 ELECTRICAL CONNECTIONS

2.Remove ground strap and discard as shown in Figure 9.Do not discard any screws. 4-wire connection with a power supply cord 4-wire connection3-wire connection: conduit

Install the conduit as follows: WARNING

Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed- loop connectors or open-end spade lugs with upturned ends shall be used. The middle (neutral) wire of the power cord or

4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire must be connected to the frame of the

range with the ground screw.

-Failure to do so can result in electrical shock, severe personal injury or death.

Follow the instructions under “ 4 CONNECT RANGE CORD” on page 5 to correctly install the strain relief.

1.Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 9.)

Remove the ground screw and retain it.

2.Remove ground strap and discard as shown in Figure 9.Do not discard any screws.

3.Insert the ground screw into the power cord ground wire terminal ring and secure it to the range frame.

4.Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block. Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block.

Tighten 3 screws securely into the terminal block.

5.Go to page 9.

4-wire connection

3-wire connection: conduit

Install the conduit as follows:

Remove the Conduit connection plate from the rear of drawer body and rotate it as shown in Figure 5. The conduit hole (11/8”) must be used.

First, prepare conduit wires as shown in Figure 10.

3 wire4 wire

or

FIGURE 10

Second, install conduit as shown in Figure 6.

For conduit installations, after purchasing a strain relief, insert it in the conduit hole (11/8”). Then install the conduit through the body of strain relief and fasten the strain relief with its ring. Reinstall the bracket.

For conduit connections :

If the wire in the conduit is copper it must be 8 or 10 AWG wiring.

If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring.

1.Loosen the lower 3 screws from the terminal block. (Refer to Figure 11.)

2.Insert the bare wire (white/neutral) end through the center terminal block opening.

Do not remove ground strap connections.

3.Insert the two side bare wire ends into the lower left and the lower right terminal block opening.

Tighten the 3 screws securely into the terminal block. (approximately 35 - 50 IN-LB)

4.Go to page 9.

3-wire connection

ENGLISH

FIGURE 9

FIGURE 11

7

Page 7
Image 7
LG Electronics LRE3012S wire connection with a power supply cord, wire connection conduit, Install the conduit as follows