6-5 REFRIGERATING CYCLE
▼Troubleshooting Chart
CAUSE
|
|
| PARTIAL |
|
|
| LEAKAGE |
LEAKAGE |
|
| COMPLETE |
|
|
| |
RESTRICTEDBY |
|
| LEAKAGE |
|
| WHOLE | |
|
|
| PARTIAL |
|
|
| RESTRICTION |
DUST |
|
| RESTRICTION |
|
|
| |
|
|
|
|
| MOISTURE | ||
| RESTRICTION | ||
DEFECTIVE COMPRESSION |
| COMP- | |
| |||
| RESSION | ||
|
|
| |
|
|
| NO COMP- |
|
|
| RESSION |
|
|
|
|
STATE OF | STATE OF THE | TEMPERATURE | REMARKS | |
OF THE | ||||
THE UNIT | EVAPORATOR | |||
COMPRESSOR |
| |||
|
|
| ||
Freezer | Low flowing sound of | A little higher | • Refrigerant level is low due | |
compartment and | Refrigerant is heard and | than ambient | • to a leak. | |
Refrigerator don't | frost forms in inlet only. | temperature. | • Normal cooling is possible by | |
cool normally. |
|
| • restoring the normal amount of | |
|
|
| • refrigerant and repairing the leak. | |
Freezer | Flowing sound of refrigerant | Equal to ambient | • No discharging of Refrigerant. | |
compartment and | is not heard and frost isn't | temperature. | • Normal cooling is possible by | |
Refrigerator don't | formed. |
| • restoring the normal amount of | |
cool normally. |
|
| • refrigerant and repairing the leak. | |
Freezer | Flowing sound of refrigerant | A little higher | • Normal discharging of the | |
compartment and | is heard and frost forms | than ambient | • refrigerant. | |
Refrigerator don't | in inlet only. | temperature. | • The capillary tube is faulty. | |
cool normally. |
|
|
| |
Freezer | Flowing sound of refrigerant | Equal to ambient | • Normal discharging of the | |
compartment and | is not heard and frost isn't | temperature. | • Refrigerant. | |
Refrigerator don't cool. | formed. |
|
| |
Cooling operation | Flowing sound of refrigerant | Lower than | • Cooling operation restarts | |
stops periodically. | is not heard and frost melts. | ambient | • when heating the inlet of the | |
|
| temperature. | • capillary tube. | |
Freezer and | Low flowing sound of | A little higher | • Low pressure at high side | |
Refrigerator | refrigerant is heard and | ambient | • of compressor due to low | |
don't cool. | frost forms in inlet only. | temperature. | • refrigerant level. | |
No compressing | Flowing sound of refrigerant | Equal to ambient | • No pressure in the high | |
operation. | is not heard and there is | temperature. | • pressure part of the | |
| no frost. |
| • compressor. | |
|
|
|
|
▼Leakage Detection
●Observe the discharging point of the refrigerant, which may be in the oil discharging part of the compressor and in a hole in the evaporator.
| Check if compressor |
|
| YES |
| Check if frost |
|
|
|
|
|
|
|
| Check if oil |
|
|
|
| ||||||||||||
|
|
|
| forms in |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
| runs. |
|
|
|
|
|
|
|
|
|
|
| No frost |
|
| leaks. |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| Evaporator. |
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| or frost forms |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| in inlet only |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Frost formed normally |
|
|
|
|
|
|
|
|
|
| Observe the discharged |
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| amount of Refrigerant. |
|
|
|
| ||||||
|
|
|
|
|
|
|
| Normal amount |
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| None or too much | YES | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Moisture Clog |
|
|
|
| Faulty |
|
|
|
|
|
| Inject refrigerant in compressor |
|
|
|
|
|
| ||||||||||||
|
|
|
|
| Compressor. |
|
|
|
|
|
| and check cooling operation. |
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Check Compressor |
|
| Clogged by dust. |
|
|
|
|
|
|
|
|
| Gas leakage. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Frost formed normally (Find the leak and repair it) |
- 14 -