6-5 REFRIGERATING CYCLE

6-5 REFRIGERATING CYCLE

Troubleshooting Chart

CAUSE

 

 

 

PARTIAL

 

 

 

LEAKAGE

LEAKAGE

 

 

COMPLETE

 

 

 

RESTRICTEDBY

 

 

LEAKAGE

 

 

WHOLE

 

 

 

PARTIAL

 

 

 

RESTRICTION

DUST

 

 

RESTRICTION

 

 

 

 

 

 

 

 

MOISTURE

 

RESTRICTION

DEFECTIVE COMPRESSION

 

COMP-

 

 

RESSION

 

 

 

 

 

 

NO COMP-

 

 

 

RESSION

 

 

 

 

STATE OF

STATE OF THE

TEMPERATURE

REMARKS

OF THE

THE UNIT

EVAPORATOR

COMPRESSOR

 

 

 

 

Freezer

Low flowing sound of

A little higher

• Refrigerant level is low due

compartment and

Refrigerant is heard and

than ambient

to a leak.

Refrigerator don't

frost forms in inlet only.

temperature.

• Normal cooling is possible by

cool normally.

 

 

restoring the normal amount of

 

 

 

refrigerant and repairing the leak.

Freezer

Flowing sound of refrigerant

Equal to ambient

• No discharging of Refrigerant.

compartment and

is not heard and frost isn't

temperature.

• Normal cooling is possible by

Refrigerator don't

formed.

 

restoring the normal amount of

cool normally.

 

 

refrigerant and repairing the leak.

Freezer

Flowing sound of refrigerant

A little higher

• Normal discharging of the

compartment and

is heard and frost forms

than ambient

refrigerant.

Refrigerator don't

in inlet only.

temperature.

• The capillary tube is faulty.

cool normally.

 

 

 

Freezer

Flowing sound of refrigerant

Equal to ambient

• Normal discharging of the

compartment and

is not heard and frost isn't

temperature.

Refrigerant.

Refrigerator don't cool.

formed.

 

 

Cooling operation

Flowing sound of refrigerant

Lower than

• Cooling operation restarts

stops periodically.

is not heard and frost melts.

ambient

when heating the inlet of the

 

 

temperature.

capillary tube.

Freezer and

Low flowing sound of

A little higher

• Low pressure at high side

Refrigerator

refrigerant is heard and

ambient

of compressor due to low

don't cool.

frost forms in inlet only.

temperature.

refrigerant level.

No compressing

Flowing sound of refrigerant

Equal to ambient

• No pressure in the high

operation.

is not heard and there is

temperature.

pressure part of the

 

no frost.

 

compressor.

 

 

 

 

Leakage Detection

Observe the discharging point of the refrigerant, which may be in the oil discharging part of the compressor and in a hole in the evaporator.

 

Check if compressor

 

 

YES

 

Check if frost

 

 

 

 

 

 

 

 

Check if oil

 

 

 

 

 

 

 

 

forms in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

runs.

 

 

 

 

 

 

 

 

 

 

 

No frost

 

 

leaks.

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or frost forms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in inlet only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frost formed normally

 

 

 

 

 

 

 

 

 

 

Observe the discharged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amount of Refrigerant.

 

 

 

 

 

 

 

 

 

 

 

 

Normal amount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None or too much

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture Clog

 

 

 

 

Faulty

 

 

 

 

 

 

Inject refrigerant in compressor

 

 

 

 

 

 

 

 

 

 

 

Compressor.

 

 

 

 

 

 

and check cooling operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Compressor

 

 

Clogged by dust.

 

 

 

 

 

 

 

 

 

Gas leakage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frost formed normally (Find the leak and repair it)