4-3 OLP (OVERLOAD PROTECTOR)
4-3-1 Definition of OLP
(1)OLP (OVERLOAD PROTECTOR) is attached to the Compressor and protects the Motor by opening the circuit to the Motor if the temperature rises and activating the bimetal spring in the OLP.
(2)When high current flows to the Compressor motor, the Bimetal works by heating the heater inside the OLP, and the OLP protects the Motor by cutting off the current flowing to the Compressor Motor.
4-3-2 Role of the OLP
(1)The OLP is attached to the Sealed Compressor used for the Refrigerator. It prevents the Motor Coil from being started in the Compressor.
(2)For normal operation of the OLP, do not turn the Adjust Screw of the OLP in any way.
(OVERLOAD PROTECTOR cross section)
4-4 TO REMOVE THE COVER PTC
1) Remove the Cover Back M/C.
(2) Remove the screw on Cover PTC. |
| 12345678 |
330 FBYY |
Electrical characteristics part number
Customer part number
Lot code/ date code
Physical termination part number
Part
No. Name Base, phenolic
(UL 94
Movable arm support, plated steel
Stationary contact support, plated steel
Heater support, plated steel
Heater, resistance alloy
Disc, thermostatic alloy
Movable arm, spring temper copper alloy
Contact, movable, silver on copper
Contact, stationary, silver on copper
Slug, plated steel
Cover, polyester (UL 94 V
Pin connector, plated copper alloy (To engage 2.33/2.66 mm dia. pin)
1 |
Figure 11
(3)Remove two Housings on upper part of Cover PTC.
(4)Take out the cover PTC from upper to lower position like .
2
(5) | Turn 45° in the direction of and take it out. |
(6) | Assembly in reverse order of disassembly. |
- 8 -