7-1-5 TEST Mode
1.The Test mode allows checking the PCB and the function of the product as well as finding out the Defective part in case of an error.
2.The test button is on the main PCB of the refrigerator (Test S/W). The test mode will be cleared in 2 hours regardless of the type of test mode.
3.While in the test mode, the ADJUST button will not operate.
4.After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5.If an error (such as a sensor failure) is detected while in the test mode, the test mode is cleared and the error code is displayed.
6.While an error code is displayed, the test mode will not be activated even if the test button is pushed.
MODE | MANIPULATION |
| CONTENTS | REMARKS |
|
|
|
|
|
TEST1 | Push the test button | 1. | Continuous operation of the COMP |
|
| once. | 2. | Continuous operation of the freezer fan |
|
|
| 3. | Defrosting Heater OFF |
|
|
| 4. Every DISPLAY LED ON |
| |
|
|
|
|
|
TEST2 | Push the test button | 1. | COMP OFF | Reset if the |
| once while in | 2. | Freezer FAN OFF | temperature of the |
| TEST MODE 1. | 3. | Defrosting heater ON | Defrosting sensor is |
|
| 4. | 1, 3, 5 LED ON | 50°F(10°C) or more. |
|
|
|
| |
Reset | Push the test button | Reset to the default setting | The compressor will | |
| once while in |
|
| Start after a |
| TEST MODE 2. |
|
| delay. |
|
|
|
|
|
- 18 -