LG Electronics LSU090HE, LSN090CE, LSU120CE, LSU090CE, LSN180CE, LSN120HE, LSN120CE Forming The Piping

Models: LSN120HE LSN240CE LSU090CE LSU240CE LSN120CE LSN180CE LSU180HE LSU180CE TRUE LSN090CE LSN240HE LSN090HE LSU090HE LSU120CE

1 83
Download 83 pages 52.83 Kb
Page 30
Image 30

FormingThePiping

Form the piping by wrapping the connect- ing portion of the indoor unit with insula- tion material and secure it with two kinds of vinyl tapes.

If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appro- priately.

In cases where the outdoor unit is installed below the indoor unit perform the following.

Tape the piping, drain hose and connecting cable from down to up.

Secure the tapped piping along the exterior wall using saddle or equivalent.

Seal small openings around pipings with a gum type sealer.

Taping

Drain hose

Pipings

Connecting cable

Trap is required to prevent water from entering into electrical parts.

In cases where the Outdoor unit is installed above the Indoor unit perform the following.

Tape the piping and connecting cable from down to up.

Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room.

Fix the piping onto the wall by saddle or equiva- lent.

Seal a small opening around the pipings with gum type sealer.

Trap

Trap

30Room Air Conditioner

Page 30
Image 30
LG Electronics LSU090HE, LSN090CE, LSU120CE Forming The Piping, Seal small openings around pipings with a gum type sealer