How
to
Attach
Drain
Pan
(Optional)

































The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the air) is drained to the outside.
In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed from the air may cause some water to collect. To remove this excess water you can install the drain pan as detailed below.
1Take the drain pan which is located in the air discharge.
2Remove the hole rubber from the
3Install the drain pan to the right corner of the cabinet with 4 (or 2) screws.
4Connect the drain hose of 3/5" inside diameter to the outlet located at the bottom of the drain pan.You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied).
CABINET
DRAIN
PAN
SCREW
DRAIN HOSE
12