RS-232CControlling the Multiple Product

Transmission / Receiving Protocol

21. Tile H Position(Command : d e)

To set the Horizontal position.

Transmission

[d][e][][Set ID][][Data][x]

Data Min : 00H ~ Max : 64H

Refer to ‘Real data mapping’ page A8.

Acknowledgement

[e][][Set ID][][OK/NG][Data][x]

22. Tile V Position(Command : d f)

To set the Vertical position.

Transmission

[d][f][][Set ID][][Data][x]

Data Min : 00H ~ Max : 64H

Refer to ‘Real data mapping’ page A8.

Acknowledgement

[f][][Set ID][][OK/NG][Data][x]