| Controlling the Multiple Product | |
|
|
|
Transmission / Receiving Protocol
23. Tile ID Set(Command : d i)
▲
To assign the Tile ID for Tiling function .
Transmission
[d][i][][Set ID][][Data][x]
Data Min : 00H ~ Max : 10H (Hexadecimal code)
Acknowledgement
[i][][Set ID][][OK/NG][Data][x]
24 Natural Mode (In Tilemode) (Command : d j)
▲
The image is omitted by the distance between the screens to be naturally shown.
Transmission
[d][j][][Set ID][][Data][x]
Data 0 : Natural Off 1 : Natural On ff : Read Status
Acknowledgement
[j][][Set ID][][OK/NG][Data][x]
25. Elapsed time return(Command : d l)
▲
To read the elapsed time.
Transmission
[d][l][][Set ID][][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[l][][Set ID][][OK/NG][Data][x]
*The data means used hours. (Hexadecimal code)
A15