Damper Damper
ClosedOpen
Lintel
Combustion Air Actuator (when installed)
Figure 3
Chase Enclosure - Indoor Installation
Insulate Joists
Same As Ceiling
Draft Stops
Firestop
CTDT
Termination
Note: Non-
Combustible
Chase
Flashing
Must Be
Used To
Cover
Chase
Opening
Optional
Insulation
In Outside
Walls Of
Chase
8'
Level
Solid
Continuous
Surface
| Outside |
Insulation | Base |
(Thermal Barrier)
Figure 4
LOCATION OF FIREPLACE
Carefully select the proper location for heat circulation, aesthetics, chimney obstructions, air inlet location and clearance to side wall(s). With proper
When locating the fireplace, consideration must be given to combustibles and final finishing. See Figure 5 and confine the final location of combustible finish materials to the "Safe Zone."
DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face.
Indoor Locations - Carefully consider the position of the fireplace opening with respect to the location of adjacent or nearby stairwells, bath or kitchen exhaust fans and/or return air registers for forced air furnaces/air conditioners that could cause a smoking fireplace condition if the house is tightly insulated.
Indoor Locations - Top View
| Hearth |
| Hearth |
Figure 5 | Optional |
Outside Chase |
CAUTION
To ensure that the outside air kit remains open for an outdoor installation,thisfireplaceshould not have a combustion air gate control installed
ATTENTION
Assurer que les restes extérieurs dekitd’airouvertspouruneinstallation extérieure,cettecheminée n’ontpasunecommandedeporte d’air de combustion a installé
Outdoor Locations - Carefully consider the position of the fireplace opening with respect to the location of adjacent or nearby stair- wells, doors, windows, walk ways and over hanging trees, patios and wires.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
When choosing a location, care must be taken to avoid places where flooding or running water may be a problem.
DO NOT place furniture or other items such as plants or decorative objects within 60” of the fireplace front face.
Outdoor Locations - Top View
LIVING SPACE
| Air Inlet (inlet | |
Optional | must be free of | |
any obstructions) | ||
Hearth | ||
| ||
Extension | PATIO | |
|
Figure 6
Restrictions for Outdoor installations:
•Outside Air Kit must be installed and fully open on the outdoor installation. On the indoor installation is optional unless mandated by local building codes.
•Minimum chimney height for the outdoor in- stallation is 7' 9" (one 4 foot pipe section).
•Minimum 2" chimney clearance is required when system height is less than 15'.
•
Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in
Figure 7.
CLEARANCES
Minimum clearance to combustibles for the appliance is as follows: sides and back - 1” (25 mm), floor - 0” (0 mm), adjacent wall - 12” (305 mm), ceiling - 37 1/2” (953 mm).
Note: Clearance at the nailing tab is 0" (0mm)
(see Figure 25).
Note: Adjacent wall considerations are for an adjacent wall on only a single side. Walls should not be placed at minimum distance at both sides of the fireplace.
Frame Surface Not to Be Covered
With Combustible Materials
12" | Wall |
| Covering |
| 45° |
1"
Door
Opening
Safe
12" Zone
Figure 7 Clearances
5