Damper Damper

ClosedOpen

Lintel

Combustion Air Actuator (when installed)

Figure 3

Chase Enclosure - Indoor Installation

Insulate Joists

Same As Ceiling

Draft Stops

Firestop

CTDT

Termination

Note: Non-

Combustible

Chase

Flashing

Must Be

Used To

Cover

Chase

Opening

Optional

Insulation

In Outside

Walls Of

Chase

8'

Level

Solid

Continuous

Surface

 

Outside

Insulation

Base

(Thermal Barrier)

Figure 4

LOCATION OF FIREPLACE

Carefully select the proper location for heat circulation, aesthetics, chimney obstructions, air inlet location and clearance to side wall(s). With proper pre-planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly. See Figures 5 & 6 for examples.

When locating the fireplace, consideration must be given to combustibles and final finishing. See Figure 5 and confine the final location of combustible finish materials to the "Safe Zone."

DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face.

Indoor Locations - Carefully consider the position of the fireplace opening with respect to the location of adjacent or nearby stairwells, bath or kitchen exhaust fans and/or return air registers for forced air furnaces/air conditioners that could cause a smoking fireplace condition if the house is tightly insulated.

Indoor Locations - Top View

 

Hearth

 

Hearth

Figure 5

Optional

Outside Chase

CAUTION

To ensure that the outside air kit remains open for an outdoor installation,thisfireplaceshould not have a combustion air gate control installed (OAKG-OD). If this unit is installed indoors, you must install the outside combustion air cover provided or an optional outside air kit gate (OAKG-OD) before the fireplace is framed in place.

ATTENTION

Assurer que les restes extérieurs dekitd’airouvertspouruneinstallation extérieure,cettecheminée n’ontpasunecommandedeporte d’air de combustion a installé (OAKG-OD). Si cette unité est installée à l’intérieur, vous devez installer la couverture extérieure d’air de combustion fournie ou une porte extérieure facultative de kit d’air (OAKG-OD) avant que la cheminée soit encadrée en place.

Outdoor Locations - Carefully consider the position of the fireplace opening with respect to the location of adjacent or nearby stair- wells, doors, windows, walk ways and over hanging trees, patios and wires.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

When choosing a location, care must be taken to avoid places where flooding or running water may be a problem.

DO NOT place furniture or other items such as plants or decorative objects within 60” of the fireplace front face.

Outdoor Locations - Top View

LIVING SPACE

 

Air Inlet (inlet

Optional

must be free of

any obstructions)

Hearth

 

Extension

PATIO

 

Figure 6

Restrictions for Outdoor installations:

Outside Air Kit must be installed and fully open on the outdoor installation. On the indoor installation is optional unless mandated by local building codes.

Minimum chimney height for the outdoor in- stallation is 7' 9" (one 4 foot pipe section).

Minimum 2" chimney clearance is required when system height is less than 15'.

Onlynon-combustiblematerialsareallowed onthefrontface(FrontFireplaceFrame)and aroundtheperimeterwithin5”(fulllengthof top spacers) on the top and 1/2" on the sides (see Figures 1, 51 & 52).

Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in

Figure 7.

CLEARANCES

Minimum clearance to combustibles for the appliance is as follows: sides and back - 1” (25 mm), floor - 0” (0 mm), adjacent wall - 12” (305 mm), ceiling - 37 1/2” (953 mm).

Note: Clearance at the nailing tab is 0" (0mm)

(see Figure 25).

Note: Adjacent wall considerations are for an adjacent wall on only a single side. Walls should not be placed at minimum distance at both sides of the fireplace.

Frame Surface Not to Be Covered

With Combustible Materials

12"

Wall

 

Covering

 

45°

1"

Door

Opening

Safe

12" Zone

Figure 7 Clearances

5