Assemble the Air Gate and Arm as shown.
Air Gate Assembly
Air Gate Arm
Air Gate Assembly
Air Gate Arm
When assembled onto appliance, the notch here must be positioned as shown
Figure 9- Outside Air Kit Gate
IMPORTANT! IF THE AIR GATE IS INSTALLED UPSIDE DOWN (WITH THE NOTCH POSITIONED ON THE UPPER HALF) IT WILL NOT WORK PROPERLY. REFER TO FIGURE 9.
c. Ensure the air gate arm remains attached to the air gate, secure the Air Gate to the fireplace, with the screws provided, as shown
in Figures 12 & 13.
d. Verify the mechanism is working by pulling to open and pushing to close.
3.Install the Outside Air Collar with the screws removed earlier (see Figure 14).
Right Outside Panel on Fireplace
Position the Air Gate Assembly as Shown
Figure 10 - Air Gate Assembly to Fireplace
Using a screwdriver bend this tab outward, if necessary, for the arm to clear the opening
FireboxArm
Front Face
Side Frame
Opening
Feed The Arm Through Side Frame Opening
Figure 11 - Air Gate Arm in Front
Align Air Gate Assembly to Opening
Figure 12 - Position Air Gate
Secure Air Gate Assembly 4 Places
Figure 13 - Install Screws
Reinstall Outside Air Collar
Figure 14 - Reinstall Connector
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
4.Install an Outside Air Kit (with duct and hood) per the instructions provided with kit.
a.If the outside air kit is NOT installed, you must install the Outside Air Cover provided with the instructions kit.
b.If an outside air kit IS installed, the Outside Air Kit Gate must be installed (see Page 23 of ordering information).
The Outside Air Kit Gates are required on all indoor installations only. They are not approved for use on oudoor installations.
Air Gate Operation Instructions
Install the Air Gate Kit per the instructions provided with kit (see Page 23 for ordering information).
Air Gate Kit (purchased separately)
Combustion Air Actuator
Pull Forward to Open,
Push Back to Close
Figure 15
To operate, push the end of the actuator arm to the left as shown in Figure 15, until it "pops" free of its "locked" position. Pull the actuator forward to open the combustion air door, and push it back to close. To "lock" the combustion air door closed, ensure the actuator is pushed all the way back then push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening.
Operate the actuator through several cycles including the "lock" position. Ensuring proper operation and freedom of movement. Return the actuator arm to the locked position.
7