LA GARD Locks BV
Internet: http://www.lagard.nl |
Kantooradres: | Postadres: |
Vlijtstraat 40 | Postbus 127 |
H.R. te Arnhem nr: 09087869 | Tel: (+31) 314 376 876 |
BTW nr: NL 8038.72.987.B01 | Fax: (+31) 314 376 878 |
OPERATING INSTRUCTIONS LG 39E Multi User Combogard /Swingbolt
Keypad 3035, 3710, 3750 or 3750K with reading contact | Lock 39E |
LED
Contact of the audit trail
37503750K
30353710
Generally
Each pressing of a key is confirmed by a signal (an acoustic signal and a LED flash). A valid code is followed by a double signal, an invalid code by a triple signal. After an interval of more than
Code entering: | Enter the |
a) Operation with parallel code: | a double signal is followed. |
(manager mode) | Manager code: 1234567 |
b) Operation with dual codes: | |
(must be programmed) | For opening two valid codes must be entered. |
| Manager code: 123456 and User ID# 654321 |
Opening: | Combogard: Enter the code and (after double signal) turn the |
| entry clockwise within 3 seconds unto the hold. The lock is open |
| and the entry is rotated. |
| Swingbolt: Enter the code and (after double signal) turn the |
| handle within 3 seconds into the OPEN position. |
| If the lock is not opened within 3 seconds, it is automatically |
| locked again. |
Locking: | Combogard: Turn the entry |
| The lock is automatically closed and the entry stands straight. |
| (Check this by trying to turn the entry back again) |
| Swingbolt: Turn the handle into the CLOSE position. |
| The lock is automatically locked; check this by trying to turn the |
| handle into “OPEN” position. |
I M P O R T A N T Check the lock to be locked.
Wrong try penalty: | After four invalid codes, the entry is blocked for about 5 |
| minutes. During this period, the lock signals at |
| intervals. After this time penalty, the entry of every second |
| invalid code initiates a new 5 minutes delay period. |
| The key pressing is refused with a triple signal. |
Change of code: | The user can change its code anytime. |
(always with open door) | Enter the code and keep pressed the last number until second |
| double signal (LED is on), press the “0” and enter the new code |
| (double signal), enter the new code once more for confirmation |
| (double signal). |
| The new code is now valid. If mistakes are made while |
| changing the code or if an interval occurs of more than 10 |
| seconds, the old code remains valid and the entire sequence |
| has to be |
| Test the new code several times by open door! |
LG 39E Combogard EN | 1 |
Revise: 1 |
Datum: