LA GARD Locks BV
Internet: http://www.lagard.nl |
Kantooradres: | Postadres: |
Vlijtstraat 40 | Postbus 127 |
H.R. te Arnhem nr: 09087869 | Tel: (+31) 314 376 876 |
BTW nr: NL 8038.72.987.B01 | Fax: (+31) 314 376 878 |
Manual programming | LG 39E Multi User |
|
Factory Mode | The lock maybe mounted in the factory mode. It opens when | |
| pressing key “1” and it sends a silent alarm signal. | |
| The advantage is that there is only 1 version storage and an | |
| easy use during mounting. | |
|
| |
Exit the | Keep pressed the key “0” until the double signal | |
| seconds). Now the manager code is 555555. | |
|
| |
Code length and program selection | The code length and program selection are made with the | |
function “8” in a group of 2 digits. The first digit is the code | ||
| length and the second one is the program number. | |
| Program 0 = Manager mode (operation with parallel code) | |
| Program 1 = Manager mode with delay override | |
| Program 2 = Operation with two codes | |
| Program 3 = Two code operation with delay override | |
| Program 4 = Manager mode with alarm | |
| Program 5 = Manager with alarm and with delay override | |
| Program 6 = Two code operation with alarm | |
| Program 7 = Two code operation, alarm and delay override | |
|
| |
Programming | Enter the manager code “555555” and keep pressed the | |
(function 8) | last number until the double signal is repeated (LED is on) | |
| and enter “8”. Enter the group of | |
| program number) double signal and repeat the group for | |
| confirmation (double signal). | |
| In case of the | |
|
| |
Install (Enable) user | Enter | |
(function 1) | stays on. Press „1“ (double signal) and enter | |
| „1“ (double signal). Enter user code (double signal) and to | |
| confirm, enter the code again. Double signal and LED | |
| extinguished. | |
| In case a new code is not accepted | |
| is too similar to an already existing code. Select new code. | |
| NOTE: Users who are not installed in this stage will be | |
| blocked after changing the manager code! | |
|
| |
Program “freeze” | After changing the manager code the program is „frozen“ and | |
| the program settings can only be changed after a reset to | |
| Factory Mode. | |
|
| |
Reset to Factory Mode | In case the manger code is lost or the setting of the lock has | |
| to be changed, a reset can be executed by means of the | |
| ||
| entry. | |
| Push the "0" button for ca. 3 minutes (or leave it for | |
| 10minuts powerless) and plug the | |
| connection of the lock. Wait until a longer signal. (0,5 sec) | |
| The | |
| ||
| The lock is in FACTORY MODE. Disconnect | |
| plug battery back again. Lock opens with “1”. |
Safety notice: Do not assign code to the users of no use for the time being.
Remove the codes. (Function 3 and user number) | |
LG 39E Combogard EN | 3 |
Revise: 1 |
Datum: