![Silent alarm:](/images/new-backgrounds/51505/515053x1.webp)
LA GARD Locks BV
Internet: http://www.lagard.nl |
Kantooradres: | Postadres: |
Vlijtstraat 40 | Postbus 127 |
H.R. te Arnhem nr: 09087869 | Tel: (+31) 314 376 876 |
BTW nr: NL 8038.72.987.B01 | Fax: (+31) 314 376 878 |
Silent alarm: | If feature is active AND optional alarm box or | |||
(must be programmed) | If the last digit is chosen one higher (+1) when entering the code, the lock | |||
| will open as usual (double signal), but at the same time the alarm box is | |||
| activated. Example: Combination: 471147 | Alarm code: 471148 | ||
Time delay for opening: | If feature is active: |
|
|
|
(Must be programmed) | After entering a valid code (double signal) the delay period starts, the LED | |||
| flashes red each |
|
| |
| At the end of the delay period the Open window starts, the LED flashes | |||
| each second and the lock beeps every 2 seconds. | |||
| To open the lock, a valid code has to be entered during the Open window. | |||
| If the Open window expires without the lock being opened, then the lock is | |||
| secured again with the Time delay. |
|
| |
| Delete current delay time: press key “0” |
| ||
| Extend current delay times: enter valid code. The delay period will start | |||
| again. |
|
|
|
Time delay override: | The user ID# 9 (money carrier) can open immediately. At the operation | |||
(Must be programmed) | with two codes the ID# 9 is entered as the second code. | |||
Power supply: | When the batteries are running low, the lock will signal for about 3 | |||
| seconds while being opened. The batteries then have to be changed. | |||
| Use DURACELL ALKALINE batteries only! |
| ||
| The codes are stored in the lock also without power supply. | |||
| 3710, 3750 and 3750K: Battery compartment is in the bottom of the entry. | |||
| 3035: Open battery box (inside door) and insert new batteries. | |||
| If the batteries have not been changed in time and the tension does not | |||
| suffice to cancel the lock‘s blocking feature, a new 9V DURACELL | |||
| ALKALINE battery can be pressed onto the contacts on the entry, until | |||
| the code has been entered and the entry is rotated. | |||
| When Time Delay is programmed, use a battery clip (on general sale). | |||
| Black upper position, red lower position. |
| ||
| When connected to the alarm equipment through the interlock device “SP“ | |||
| then the power supply is secured from this place. | |||
Safety notice: | • Change the manager code immediately |
| ||
| • Do not use personal data (birth date) as a code | |||
| • Keep the code from unauthorised use |
| ||
LED and acoustic signals: | 1 x short signal | enter confirmation | ||
| 2 x short signal | valid code entered | ||
| 3 x short signal | wrong code, not accepted | ||
| 6 x short signal | remote disable, blocked by the alarm | ||
|
| equipment |
| |
| LED signal each 10sec. 1 flashing | blocking time after a wrong tries | ||
| LED signal each 2sec. |
| Time delay before opening is running | |
| Alternate LED and acoustic signals | Time window for opening is running |
A series of triple signals, ca. 3seconds: Low battery
|
| Still possible ca. 10 openings. | |
|
| According to the battery capacity there may be also less signals | |
|
| therefore the battery change should be made also in case of | |
|
| double signals | |
|
| Use 9V DURACELL ALKALINE batteries only! | |
|
|
|
|
LG 39E Combogard EN | 2 |
| |
Revise: 1 |
| ||
Datum: |
|
|