Chapter 5: Recording/Playback

Input signal selection

According to the analog audio signal fed to the [ANALOG IN] connector, set the LINE-MIC switch to "LINE" or "MIC". When you select "MIC", set the phantom power switch to "48V", "DM" or "T12" appropriately according to the microphone connected.

LINE

 

MIC

LINE

 

MIC

LINE

 

MIC

LINE

 

MIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT SEL

LINE-MIC switches and

48V

DM T12

48V

DM T12

48V

DM T12

48V

DM T12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phantom power switches

130

 

200

130

 

200

130

 

200

130

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Hz)

 

50

 

300

50

 

300

50

 

300

50

 

300

HPF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-12

-6

OFF

-12

-6

OFF -12

-6

OFF -12

-6

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(dB/oct)

 

High-pass filter setting

The PD204 is equipped with the high-pass filter circuit. The cutoff frequency can be adjusted within the range between 50 Hz and 300 Hz, while the filter slope can be selected between -6 dB/oct. and -12 dB/oct.

The filter is useful to eliminate the wind noise during location recording or unnecessary low frequency noise when recording voice or sound. You can make filter setting for each channel individually.

Limiter setting

LINE

 

MIC

LINE

 

MIC

LINE

 

MIC

LINE

 

MIC

 

 

 

 

 

 

 

 

 

 

 

INPUT SEL

48V

DM

T12

48V

DM

T12

48V

DM

T12

48V

DM

T12

130

 

200

130

 

200

130

 

200

130

 

200

 

 

 

 

 

 

 

 

 

 

 

(Hz)

50

 

300

50

 

300

50

 

300

50

 

300

 

 

 

 

 

 

 

 

 

 

 

HPF

-12

-6

OFF

-12

-6

OFF

-12

-6

OFF

-12

-6

OFF

 

 

 

 

 

 

 

 

 

 

 

(dB/oct)

[HPF] controls

and switches

By using the limiter when recording microphone sound, the signal level is prevented from exceeding a certain level. In result, the signal level fluctuation is suppressed. By default, the threshold of the PD204 limiter is set to -12 dB under the 24-bit full-scale level (all bits are ON) and the compressed ratio is set to 1:5. The limiter attack time is fixed to 5 ms, while the release time is fixed to 200 ms. You can set limiter parameters using the "Limiter parameter" menu item in the "SYS SETUP" menu of the MENU mode (see page 156 for details).

<Note>: When you use the limiter function, see also "Gain adjustment" on the page 81.

Location Recorder Model PD204

79

Page 79
Image 79
Fostex PD204 owner manual Input signal selection, High-pass filter setting, Limiter setting