Chapter 3: Names and Functions

4.[TIME CODE OUT] connector (XLR-3-32 type/balanced)

Outputs time code.

1

2

3

1GND

2HOT

3COLD

5.[TIME CODE IN] connector (XLR-3-31 type/balanced)

Inputs external time code.

2 1

3

1GND

2HOT

3COLD

6.[WORD IN] termination switch

Terminates the word input signal by setting the switch to "ON".

7.[WORD/VIDEO IN] and [WORD OUT] connectors (BNC type)

The [WORD/VIDEO IN] connector receives word or video clock. It automatically detects the clock type (word or video).

The [WORD OUT] connector feeds a word clock.

8.[9P-REMOTE] connector (D-sub 9-pin/female)

Not currently supported. Prepared for the future expansion.

9.Angle adjustment arm

10.[PARALLEL] connector (MINI DIN 8-pin)

This connector accepts parallel remote signals for controlling the PD204 externally. You can control the following nine operations remotely.

1

PLAY

6

CUE point registration

2

STOP

7

PAUSE

3

RECORD

8

FILE

 

 

 

 

 

 

4

REWIND

9

FILE

 

 

 

 

5

F. FORWARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Operation>

When each terminal is grounded, the corresponding function is active.

Note that you can always control the PD204 via this connector regardless of the set- ting of the [PANEL LOCK] key on the panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

PLAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

STOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

REC

 

8

 

 

7

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

GND

5

 

 

 

 

 

3

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

SHIFT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

6

REW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

DC-OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

FF

SHIFT + STOP

CUE

SHIFT + REC

PAUSE

 

 

 

 

 

 

SHIFT + REW

FILE

 

 

 

 

 

 

SHIFT + FF

FILE

 

 

 

 

(*) V BATT (12V), Max 500mA.

It is output regardless of power on/off.

Location Recorder Model PD204