Chapter 8: MENU mode/SYS SETUP menu

<Note>: To make continuous recording, the next partition to the current partition must have enough recordable space. It is recommended that no recording has been made to the next partition before making continuous recording.

The following shows how continuous recording is made depending on the setting of the “Max file length” item in the “SYS SETUP” menu of the MENU mode.

It is assumed to attempt to record 6GB audio data to partition 1 (PT01) with “Auto part. link” set to “On”.

• When “Max file length” is set to “4GB”:

Data is record to “4GB” and “0.5GB” files on partition 1 (PT01), and the rest 1.5GB data is recorded to a file on partition 2 (PT02). (The created files have sequential file numbers.)

Partition 1 (P01)

Partition 2 (P02)

4GB0.5GB

1.5GB

SCENE_001.wavSCENE_002.wav

SCENE_003.wav

• When “Max file length” is set to “2GB”:

Data is record to two “2GB” and a “0.5GB” files on partition 1 (PT01), and the rest 1.5GB data is recorded to a file on partition 2 (PT02). (The created files have sequential file numbers.)

Partition 1 (P01)

Partition 2 (P02)

2GB 2GB 0.5GB

1.5GB

SCENE_001.wav SCENE_002.wav SCENE_003.wav

SCENE_004.wav

If data is too large for two partitions, partition 3 (PT03) is used.

If the next partition does not have recordable space, recording ends. If “Auto part link” is set to “Off”, continuous recording is not made.