Chapter 8: MENU mode/TC SETUP menu

Internal TC generator power-off timer [TC PWR Timer]

Using the "TC PWR Time" item, you can set the time until the TC generator turns off after turning off the main unit.

It is set to five minutes by default, so after the PD204 is turned off, the internal TC generator continues working for five more minutes.

1)When the unit is stopped, press the [SHIFT] key to light the [SHIFT] indicator, followed by the [TIME/TC SET] key.

The display now shows the TC SETUP menu screen.

2)Use the [MENU] dial to select the “RecIn via ExtTC” menu item, and press the [ENTER/YES] key.

The current setting starts flashing and you can now select the desired option.

Flashing

3)Use the [MENU] dial to select the desired option, and press the [ENTER/YES] key to confirm your setting.

Options

You can select from among “0min”, “5min”, “10min”, “15min”, “30min”, “1hour”, “2hour”, “4hour”,

“8hour” and “Cont.” (Continue) (the default is “5min”).

<Note>: When any option except "0min" is selected, the display backlight flashes weakly and slowly after turning off the PD204, indicating that the internal TC gen- erator is still working. We recommend selecting shorter time for the "TC PWR Timer" item when operating the unit on battery.