Fostex PD204 owner manual Analog OUT nominal level setting Stereo out level

Models: PD204

1 220
Download 220 pages 50.23 Kb
Page 158
Image 158

Chapter 8: MENU mode/SYS SETUP menu

ANALOG OUT nominal level setting [Stereo out level]

The "Stereo out level" menu item selects the nominal output level of the [ANALOG OUT]. According to the device connected to the [ANALOG OUT] connector, select the level appropri- ately.

1)While the unit is stopped, press the [SHIFT] key to light the SHIFT indicator, followed by the [ENTER/YES] key.

2)While “SYS SETUP” is highlighted, press the [ENTER/YES] key.

The display now shows the SYS SETUP menu screen.

3)Use the [MENU] dial to select the “Stereo out level” menu item and press the [ENTER/YES] key.

The current setting starts flashing and you can now select the desired option.

Flashing

Options

Selectable between “+4dBu”, “-10dBu” and “-60dBu” (the default is “+4dBu”).

4)Use the [MENU] dial to select the desired option and press the [ENTER/YES] key to confirm your setting.

5)Press the [EXIT] key repeatedly until you exit the MENU mode.

158 Location Recorder Model PD204

Page 158
Image 158
Fostex PD204 owner manual Analog OUT nominal level setting Stereo out level