Chapter 8: MENU mode/SYS SETUP menu

Pause cancel time setting [Pause time]

The “Pause time” menu item sets the pause cancel time. After the pause cancel time has passed since the recorder entered the pause mode, the recorder automatically cancels the pause mode and stops.

1)While the unit is stopped, press the [SHIFT] key to light the SHIFT indicator, followed by the [ENTER/YES] key.

2)While “SYS SETUP” is highlighted, press the [ENTER/YES] key.

The display now shows the SYS SETUP menu screen.

3)Use the [MENU] dial to select the “Pause time” menu item and press the [ENTER/YES] key.

The current setting starts flashing and you can now select the desired option.

Flashing

Options

You can set the time between “0.1min.” and “9.9min.” in 0.1 minute step or infinity ()

(the default is “1.0min”).

4)Use the [MENU] dial to select the desired option and press the [ENTER/YES] key to confirm your setting.

5)Press the [EXIT] key repeatedly until you exit the MENU mode.